Active filter

Eliminate harmonic distortion in HVAC/R applications for maximized grid capacity, systemwide operational efficiency and reliability with the Active Filter from Danfoss Drives. The filter is constructed from VLT variable frequency drive technology and engineered to mitigate harmonics to a lower level than passive and 18-pulse filter options.

03/01/2008


Eliminate harmonic distortion in HVAC/R applications for maximized grid capacity, systemwide operational efficiency and reliability with the Active Filter from Danfoss Drives. The filter is constructed from VLT variable frequency drive technology and engineered to mitigate harmonics to a lower level than passive and 18-pulse filter options. The filter adapts and performs in various installations, while improving the power factors and canceling harmonic distortion. The improved power factor equals 1 at any load condition, and the grid capacity increases because derating transformers are not necessary when harmonic distortion is mitigated.

www.danfossdrives.com

Input 3 at QuickResponse





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me