A Standard of Care for Energy

The minimum acceptable criteria for energy efficient design should be defined because there are many conflicting publications and codes available. Since 1975, the generally accepted standard of care for designing commercial buildings for energy efficiency has been ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings.

07/01/2004


The minimum acceptable criteria for energy efficient design should be defined because there are many conflicting publications and codes available. Since 1975, the generally accepted standard of care for designing commercial buildings for energy efficiency has been ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings . It is the only national energy standard developed and maintained by an ANSI-accredited consensus process using a large technically qualified and balanced group of stakeholders. The 1992 Federal Energy Policy Act (EPACT) uses 90.1 to set the minimum requirements that state energy codes are obligated to meet. The U.S. Dept. of Energy (DOE) has set July 15, 2004 as the deadline for states to certify that their energy codes equal or exceed the requirements in Standard 90.1-1999.

Most states have adopted or are considering adoption of national model codes. The International Energy Conservation Code (IECC) is the most widely adopted energy code and offers two compliance paths. Chapter 7 references 90.1 as one option for compliance. That being said, most designs complying with IECC do not use the 90.1 option, as users often perceive the 90.1 criteria to be more expensive and more complex. Furthermore, IECC also allows another less stringent and less comprehensive option to achieve compliance by following its Chapter 8 requirements. However, there are mandatory provisions in 90.1 that are not in Chapter 8, such as load calculations, controls, balancing and plumbing requirements. Thus, compliance with IECC does not necessarily mean compliance with 90.1 and EPACT.

Some states also allow the use of DOE building code software COM check -EZ as a method to demonstrate compliance with IECC. However, COM check -EZ does not cover all of the requirements of either IECC or 90.1. While it is accepted for a building permit, it does not necessarily mean that all relevant provisions of either IECC or 90.1 are met.

Another model code is the NFPA 5000 Building Construction and Safety Code , which uses 90.1 as the sole criteria for energy conservation.

State and local governments tend to modify the model codes they adopt. The question then becomes whether individual building designs should comply with the local energy code or with 90.1, or both. I believe the standard of care for engineering practice today requires both.

The Leadership in Energy and Environmental Design (LEED) program of the U.S. Green Building Council requires compliance with 90.1. Additional points to achieve higher levels of LEED certification are available for further reductions in energy compared with 90.1. However, it must be noted that where 90.1 or its equivalent has been adopted as the local energy code, then LEED certification simply means the building meets the energy code and standard of care and should have the same energy performance as any other building built to code.

ASHRAE will complete the 2004 edition of 90.1 shortly, which will be submitted for reference in the 2006 editions of both NFPA 5000 and IECC. The two major differences compared with prior editions are more stringent lighting requirements and a complete editorial revision for simplicity. When published, 90.1-2004 will become the standard of care.

Some important conclusions can be drawn. States that adopt and enforce IECC do not comply with EPACT. Do not rely on COM check -EZ to determine compliance with IECC or 90.1. States that adopt and enforce NFPA 5000 will automatically comply with EPACT. LEED certified buildings must meet EPACT and the standard of care for energy. The only way to meet both EPACT and the standard of care is to comply with 90.1.

For more information on COM check -EZ, see "Simplified Energy Code Compliance" in the HVAC community at csemag.com .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me