6 mm universal signal conditioner has auto-reset fuse

Wago Corporation's 6 mm universal signal conditioner offers signal precision, an auto-reset fuse, and signal clipping, the company said.

08/17/2011


Wago Corporation's 857-402 Jumpflex Universal Signal Conditioner (USC) supports 456 signal combinations with exclusive input voltage range and self-resetting fuse. Courtesy: WagoWago Corporation's 857-402 Jumpflex Universal Signal Conditioner (USC) supports 456 signal combinations with exclusive input voltage range and self-resetting fuse. Unlike competitive 12.5 mm devices, the 6 mm USC offers class-exclusive signal clipping and freely scalable voltage input range — ±60 mV to a segment-leading ±200 V. Current input range is ±0.3 mA to ±100 mA.

Constant signal precision

DIP switch configurable, the USC’s 456 signal combinations reportedly maintain precise, constant values — even after reconfiguration — via factory-calibrated, laser-capable resistors. 857-402 replaces the traditional screw potentiometer with an innovative, vibration-proof momentary rocker-style switch (MRS). The MRS has no end/stop point for signal settings/adjustments and provides scalability across entire measurement range.

Auto-reset fuse

857-402’s Auto-reset Fuse protects current input against overloads without impacting input value; fuse automatically resets after overload removal.

Signal clipping:

The USC’s signal clipping feature safeguards PLCs by switching between limiting and analog behavior. Example: if a transducer’s input exceeds 20 mA, the output signal is clipped at 20 mA. This ensures output will continue functioning properly, preventing errors.

857-402 is said to incorporate Jumpflex features, including: flexible color-coded, push-in jumpers, jumper slots at every connection point, one marking tag holder, ribbon cable interface adapter, 3 way 2.5kV isolation and Cage Clamp S termination technology. The USC’s operating temperature range is -25 C to +70 C.

Wago Corporation

www.wago.com  

- Edited by Chris Vavra, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me