1st Army Headquarters Renovation

Existing building retrofit: 1st Army Headquarters Renovation; Pond and Co.

08/09/2012


This photo shows a view of the main lobby of the historic building. (Click to enlarge)Project name: 1st Army Headquarters Renovation

Location: Rock Island, Ill.

Firm name: Pond and Co.

Project type, building type: Existing building retrofit, office

Project duration: 2 years

Project completion date: May 30, 2007

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $181,000

Engineering challenges

The project was challenging in that it involved a complete HVAC and electrical renovation of a 200,000-sq-ft historic building with the most modern and secure global communications systems. The project design also achieved LEED Silver certification. The project budget required that existing mechanical and electrical equipment be reutilized to the greatest extent possible while providing for redundant system requirements due to the nature of the building operations.

Solutions

Pond MEP engineers designed a way to cross-connect existing systems to account for some of the system redundancies that were required, thereby saving approximately $1,000,000 in new equipment costs and the need for a building addition to house the additional equipment. The innovative design required a new direct digital control system to alter the HVAC equipment operations in the event a piece of equipment was down due to failure or for maintenance.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me