Velocity Is Key to Motion Control

02/01/1997


Motion control systems are generally designed to move a load along a specified path as fast as possible without damaging the load or the mechanism driving it. Heavy loads are particularly difficult to control since inertia tends to force the load off course during high acceleration maneuvers. Worse still, the stress of resisting the load's inertia can destroy not only the drive mechanism, but the load itself.

Rotating machinery, linear conveyors, and multiaxis robotic arms all share these problems, but a more familiar example of heavy-load motion control is the passenger elevator. An elevator must be able to move its occupants from floor to floor as fast as possible without making them sick. An elevator that lurches up the shaft and stops abruptly at the end of the trip will certainly meet the objective of high speed, but not passenger comfort. Conversely, a very slow elevator can transport its passengers comfortably, but at the expense of longer travel times.

Trade-offs
An acceptable trade-off between speed and stress can be achieved by carefully manipulating the velocity of the load. The accompanying figure shows three techniques for accelerating a load from a stand-still up to a final velocity of V f (distance/sec for linear motion or rad/sec for circular motion). All three techniques limit inertial forces by limiting the maximum acceleration to a value of A m (distance/sec2or rad/sec2).

Technique 1 is the fastest. The velocity of the load is simply ramped up from zero to V f , then held steady thereafter. The corresponding acceleration starts at A m immediately then drops to zero when the velocity levels off. This fast and furious technique would correspond to the lurching elevator. The abrupt changes in acceleration would cause the passengers to be pinned to the floor at take-off then thrown to the ceiling once V f is achieved.

Technique 2 also starts out with maximum acceleration, but gradually reduces the acceleration to zero so that the velocity transitions smoothly to a steady state. An elevator moving this way would still lurch up the shaft at take-off, but would cause the passengers much less stress thereafter.

Technique 3 smoothes out both the initial and final changes in velocity by starting and ending with zero acceleration. The maximum acceleration A m is achieved half way through the acceleration period. Although this technique is not as fast as the first, it would be much more comfortable for an elevator's passengers.

The mathematics
A motion controller equipped with velocity feedback could be used to implement any of these three acceleration techniques. Each would require a different velocity profile v(t) for the controller to use as a reference signal. The first velocity profile would be a simple ramp...


The second velocity profile could be represented as an exponential increase...


where K = A m /V f is a constant. The corresponding acceleration would be...


There are several mathematical formulas that would produce the 'S' shape of the third velocity profile. The one shown in the accompanying figure is given by:


where the constant

is the time required to achieve the final velocity V f . Note that this interval is roughly 57 percent longer than the time required for the first technique to achieve V f using the same maximum acceleration A m . The acceleration for the third technique is given by:

For more information, contact George Younkin, Industrial Controls Consulting; Tel: 414/929-6544.

Vance J. VanDoren Holds a Ph.D. in Control Engineering from Purdue University's School of Mechanical Engineering.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me