Protect Plant Personnel

KEY WORDSMachine control and discrete sensorsSafetyRedundant controlControl architecturesManufacturing has been a dangerous place to work since the beginning. Even as engineers have tried to design safeguards and unions try to educate members about the importance of safety, as late as 10 years ago it was not unusual to walk around a factory and see guards taken off machines and safety switches ...


KEY WORDS

  • Machine control and discrete sensors

  • Safety

  • Redundant control

  • Control architectures

Manufacturing has been a dangerous place to work since the beginning. Even as engineers have tried to design safeguards and unions try to educate members about the importance of safety, as late as 10 years ago it was not unusual to walk around a factory and see guards taken off machines and safety switches 'defeated.'

Safety is an extremely urgent concern. Of course, care and concern for plant personnel is primary. No one who comes to work in manufacturing should be put in avoidable risk. All should be well trained for those situations where some risk is involved. Further than that, injuries also cause lost production, impact quality, bring unwanted attention from regulatory agencies, and more.

European EU-Machinery Directive 98/37/EG-recognized as law in European Union (EU) countries-impacts not only European manufacturers but also any OEM desiring to sell there. End-user companies in other countries can easily integrate these methods into safety standards of their own. While this article points out risk-assessment methods under the Directive, applicable U.S. standards include those from UL, ANSI, and OSHA.

Roland Puerner, machine safety devices product manager at Siemens Energy & Automation (Alpharetta, Ga.), advises, 'Safety concerns must be addressed up front, when engineers are planning a product, system, or plant. Using integrated intelligence from sensors and drives, safety becomes part of the process' function, rather than a net for leaping into when disaster hits.



A properly documented logical process of risk assessment, such
as reflected in this chart, enables development of a much safer machine.

Design in safety

'Right now,' Mr. Puerner says, 'conventional safeguarding for machines is separated from technical evolution of standard automation. Patching together safety after-the-fact is slow and burdensome, requiring parallel wiring, special engineering tools, and redundant efforts. Addressing safety during planning and development saves time and money, and works better, too. Safety technology has to be integrated into standard controls-we call that 'Safety Integrated.''

What Mr. Puerner points out applies today and in the future. Current safety control systems require hard wiring components rather than putting safety sensors and control on an existing industrial automation network. This Dedicated safety systems make sense from more than just a legal view. Safety control must be as failsafe as possible. Safety relays contain redundancy to assure proper operation even under abnormal circumstances-like a cut wire. Industrial control networks will need some further development and refinement along with extensive testing to become accepted for safety requirements.

Joe Lazzara, Scientific Technology Inc. (STI, Fremont, Calif.) president and ceo, agrees with the trends. He states, 'The days of 'we're almost finished, let's throw the safety guards on' are over. Safety becomes an integral part of machine control with the added benefit of improved accessibility and machine esthetics yielding cleaner designs with better maintainability.'

Control engineers should consider safety from the beginning of control design. Fortunately, the elements of safety systems mirror those of control systems-sensing and control. Reno Suffi, safety product marketing manager of Omron Electronics (Schaumburg, Ill.), notes, 'With any safety system there are two crucial aspects, detection and control. The detection aspect can be achieved with safety light curtains, while safety relays can provide control.' Other detection devices include gate switches, safety floor mats, pull activated switches, two-hand operation switches, and laser area sensors.

Assess risks

The following overview of the European Directive-from Banner Engineering (Minneapolis, Minn.) and Rockwell Automation (Milwaukee, Wis.)-is not meant to replace a thorough review of applicable laws. Companies mentioned in this article are a good starting place to learn more, along with applicable regulatory bodies.

Safety control circuits are segmented into categories depending on their ability to maintain integrity in the event of failure. EN-954-1 Safety Related Parts of Control Systems establishes five levels from Category B at the lowest to Category 4 at the highest. ANSI/RIA R15.06-1999, Safety Requirements for Industrial Robots and Robot Systems, (but not part of the European Directive) also details a risk assessment and multiple levels of safety system integrity with the lowest being a 'Simple' system and the highest a 'Control Reliable' system.

Banner Engineering provides a general description of safety circuit integrity levels, not specific to a standard. It defines Basic, Single Channel, Single Channel with Monitoring, Dual Channel, and Dual Channel with Monitoring.

Basic safety system integrity may use non-safety-rated components designed to withstand their environment and integration in accordance with relevant standards. Provision for redundancy is not required.

Single Channel systems use safety-rated components with proven safety principles and designs but no provision for redundancy. Single Channel with Monitoring system incorporates Single Channel systems with a periodic check of the system, either automatically or manually during normal operation and at start-up.

Dual Channel is a redundant system that does not fail to danger if a single fault occurs, because the second independent channel maintains ability to arrest dangerous motion. To further increase safety, diverse redundancy is employed, for example, normally open switches in the first channel and normally closed in the second.

Dual Channel with Monitoring system uses redundancy combined with fully integrated checking functions. No single failure can cause loss of the safety function and any fault is detected immediately or at the next demand on the system. Once a safety critical fault is detected within the system, a safe state is maintained until the failure is corrected.

Hierarchy of risk

Rockwell Automation information points out the hierarchy of measures for eliminating risk according to the EU directive. First, the design must be inherently safe design. as part of the machine-design process.

For those machine areas where that is not possible, designers must add protective devices. These can be locked gates, safety mats, light curtains, etc.

Many times residual areas of risk cannot be dealt with by add-on devices. In those cases, risks must be contained by personal protective equipment and/or training.

General, common-sense safety tips include suitable construction materials, adequate lighting; reliable control systems; prevention of accidental, unexpected start up; and use of one or more emergency stop devices.

Two major ingredients of a safety strategy are risk assessment and risk reduction.

Good risk assessment requires a clear understanding of machine limits and functions. It involves taking a long, dispassionate view of the entire machine and all operator/maintenance interactions with it. Each potential hazard must be identified and the degree of risk to personnel must be estimated. The next step is to evaluate each risk to determine whether existing safety measures are adequate or if additional measures must be taken.

Reduce risks

All this evaluation must, of course, lead to risk-reduction efforts. After implementations are completed, then assessment must be repeated to assure the desired result was, in fact, attained.

Is all of this effort necessary? It is a legal requirement in the European Union. If your company is an OEM shipping there, then this is more than a theoretical exercise.

Always document the risk estimation. Perform the analysis logically and methodically. Have others check it. Put it in a form that others can follow if you are unavailable. While evaluating risk, include all the life stages of the machine. These will include, at minimum, installation, commissioning, maintenance, de-commissioning, normal operation, and consequences of foreseeable misuse or faults.

The term 'risk' includes both the severity of potential harm and the probability of occurrence.

Rockwell's guide to safety principles includes a suggested method for risk assessment. This is offered as a general guide to encourage methodical and documented assessment practice.

When evaluating risk, consider severity of potential injury and probability of occurrence, which includes evaluating frequency of exposure and probability of injury.

Assess injury severity

Assess the severity of injury from a hazard as either fatal, major (normally irreversible), serious (normally reversible, e.g., loss of consciousness), or minor (e.g., bruising, cuts, light abrasions).

Frequency of exposure can be classified as frequent (several times per day), occasional (daily), or seldom (weekly or less). Probability of injury can be classified as unlikely, possible, probable, certain.

Numeric values can be attached to each category yielding a total for each hazard. Comparison of hazards generates a hierarchy of hazards that can be tackled in order of severity.

It is essential to look at this process as iterative. Don't use the 'inoculation' method of safety, that is, take a small injection and be cured forever. After completing an analysis, go back and assure that applied corrective measures were appropriate and effective. Use experience with the machine to discover previously hidden hazards.

Training is an important preventive measure. After documenting the risk process, develop training materials to ensure proper equipment operation and maintenance.

It's hard to find good employees these days. Take care of the ones who are already there. Control engineers play an important role in machine safety and in protecting plant personnel.

For more suppliers, go to www.controleng.com/buyersguide; for more information, use the following circle numbers or go online at www.controleng.com/freeinfo:

Banner Engineering. www.bannerengineering.com 241

Omron Electronics. www.info.omron.com.242

Rockwell Automation. www.automation.rockwell.com 243

Scientific Technologies Inc. (STI). www.sti.com 244

Siemens E&A. www.sea.siemens.com 245



Products aid protection

Manufacturers provide a wealth of products that, when properly applied, contribute to overall safety of machines. Check out online catalogs or a local distributor for further information about products and how to apply them. Also reference Control Engineering Buyer's Guide at www.controleng.com/buyersguide.

Interlocking switches are assembled to movable guards to ensure power to the hazard will be turned off in the event of the guard door not properly close. Some interlocking switches also incorporate a locking device that locks the guard door closed and will not release it unless the machine is in a safe condition.

Two-hand controls are a common method of preventing access while the machine is in a dangerous condition. Both hands of the operator must be placed in a safe position while the machine is actuated.

When physical access is frequently required, physical guarding is too restrictive for efficient machine operation. In this case, a device is required to prevent dangerous motion while allowing access by sensing presence of the operator and isolating the power source.

Photoelectric light curtains emit a 'curtain' of harmless infrared light beams across the access point of the hazardous area. When any of the beams is blocked, the device switches off the hazard power source.

Pressure sensitive safety mats are other devices for detecting operator presence in a hazardous area.

For machinery covering a distance, such as conveyors, it is often more convenient and effective to use a cable pull device along the hazard area. These devices use a steel wire rope connected to latching pull switches, so that pulling on the rope in any direction at any point along its length will trip the switch and cut off machine power.

Source: Rockwell Automation and Banner Engineering



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me