Machine Safety: Can end user companies comply with ISO 13849-1: 2006 without design engineering resources?

ISO 13849-1: 2006, an international machine safety standard, is written for individuals who perform design responsibilities for control systems. What are end users responsibilities?

12/13/2012


ISO 13849-1: 2006 is an updated international machine safety standard intentionally written for individuals who perform design responsibilities for control systems. These responsibilities are specifically for the design of control systems for machinery and the safety-related parts of control systems. Okay, so what industry standard do end user companies reference to maintain and/or modify their installed safety-related parts of control systems?

 

Am I the only fly in the ointment?

 

By definition, in the Scope statement of ISO 13849-1 you’ll find:

 

This part of ISO 13849 provides safety requirements and guidance on the principles for the design and integration of safety-related parts of control systems (SRP/CS), including the design of software. For these parts of SRP/CS, it specifies characteristics that include the performance level required for carrying out safety functions. It applies to SRP/CS, regardless of the type of technology and energy used (electrical, hydraulic, pneumatic, mechanical, etc.), for all kinds of machinery.

 

As stated above, this international standard has targeted “designers and integrators” of the safety-related parts of control systems (SRP/CS). Obviously the writers of this standard transitioned the required approach for achieving functional safety from a qualitative methodology (Categories B, 1, 2, 3 &4 from EN 954-1: 1996) to a quantitative methodology (PL a, b, c, d & e). It is well documented that by achieving this goal the risk levels of ISO 13849-1 and IEC 62061 are exactly quantitatively comparable. Conversely, the qualitative risk levels of Categories could not mathematically compare with the quantitative SIL (safety integrity level) risk levels of IEC 62061. The lack of this ability had been a criticism of the Category methodology originated by EN 954-1 versus the SIL methodology of IEC 62061. Hurray for this international achievement!

 

In the U.S. we didn’t adopt EN 954-1 because the U.S. doesn’t adopt EN (European Norm) standards. However, we did adopt the qualitative methodologies of EN 954-1 and the Category methodology for risk levels. Additionally, U.S. industries have focused training efforts at small and medium sized companies to learn and adopt this qualitative approach to manage and implement their machine safety strategies. In many of these small and medium sized companies, oversight and implementation resources are not graduate design engineers. Yet, these companies can readily handle their responsibilities for maintenance and modification of safety-related parts of control systems using the qualitative methodologies of Categories. However, transitioning their requirements to the new quantitative methodologies of ISO 13849-1 may not be possible via in-house resources. So, how will these companies provide a safe working environment for their employees around machines when the supply channel converts to Performance Level (PL) versus Category (Cat) for certifying safety products?

 

We must remember that our OSHA laws enforce machine safety compliance to end user companies and not to designers and integrators. In Europe under the Machinery Directive legal compliance is enforced on the designers and integrators.

Are end user companies in the U.S. abandoned by a zeal to mathematically compare risk levels of hazards between two standards?

      

J.B. Titus, CFSEYour comments or suggestion are always welcome so please let us know your thoughts. Submit your ideas, experiences, and challenges on this subject in the comments section below.

 

Related articles:

Inside Machines: Does adopting ISO 13849-1:2006 change the U.S. model for compliance and enforcement?

Machine Safety – functional safety & the steps to be compliant in the US.

Machinery Directive In 4 Days Drops EN 954 and EN ISO 13849-1 Is Fully In Force – What’s Your Impact?

Is OSHA Rear View Mirror Enforcement?

Machine Safety: Is OSHA okay with my 'acceptable' risk mitigation?

 

 

Contact: www.jbtitus.com for “Solutions for Machine Safety”.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me