Embedded database for SCADA adds safety, efficiency to nuclear waste processing

McObject database technology helps BISMARC operator interface and SCADA at the Smolensk nuclear waste installation. Baltic Information Systems (BIS), a Lithuanian company founded to provide safety-related IT systems for nuclear power plants, has developed a supervisory control and data acquisition (SCADA) product called BISMARC that relies on the McObject eXtremeDB In-Memory Database System (IMDS).

01/06/2011


Baltic Information Systems (BIS), a Lithuanian company founded to provide safety-related IT systems for nuclear power plants, has developed a supervisory control and data acquisition (SCADA) product called BISMARC that relies on the McObject eXtremeDB In-Memory Database System (IMDS). A major BISMARC deployment at the Smolensk Nuclear Power Plant in Russia illustrates the data management challenges posed by real-time, safety-critical industrial control, as well as key benefits of integrating McObject’s eXtremeDB embedded database technology.

McObject provides this illustration to Control Engineering to show the BISMARC operator interface at the Smolensk installation; see more information at www.mcobject.com/january5/2011.These benefits include shorter time-to-market: BIS saved six programmer-months by using eXtremeDB rather than internally developed data management code, and gained the reliability of a proven, off-the-shelf database, a BIS senior software engineer estimated. By embedding eXtremeDB, BISMARC also gained a level of responsiveness that is demanded by real-time safety-critical processes, but is impossible to attain using a traditional on-disk, client/server, and/or SQL relational database management system, the engineer said.

The Smolensk facility – generator of some 20 billion KW hours annually, or 1/7 of Russia’s nuclear energy output – uses BISMARC to ensure safety and efficiency in nuclear waste disposal. For this deployment, engineers configured BISMARC’s distributed, redundant client/server architecture into two operator nodes and one administrator node, running on Debian Linux and off-the-shelf x86 hardware. The nodes – and their embedded eXtremeDB in-memory databases – receive a constant flow of information from the programmable logic controller (the RTP 2500 PLC from RTP Corp.) that controls nuclear waste disposal equipment.

On each node, eXtremeDB serves as a classic SCADA “tag database,” managing some 10,000 tags, or data points, that each represents an atomic unit of information such as a single input or output value. About 2,000 of the points describe the actual manufacturing process; others are system-reserved (for example, showing BISMARC’s current CPU usage). Other tags support special functions such as alarms. While the Smolensk plant uses BISMARC primarily for monitoring, the system enables operators to respond to alarms (configurable as blinking lights, sirens, etc.) by overriding the PLC and controlling machinery directly.

Performance was a key consideration in choosing an off-the-shelf database system for BISMARC. For example, the tag database used at Smolensk for nuclear waste processing is updated three times per second, and BISMARC guarantees a response time of one second or less. Actual response time is on the order of 100 milliseconds or less, BIS Senior Software Engineer Aleksej Penkov said.

The Smolensk BISMARC deployment actually uses two database management systems: the eXtremeDB IMDS to support real-time, embedded processes, and an external PostgreSQL relational DBMS for archiving and provisioning. Most tags consist of both static and dynamic (real-time) attributes. The static characteristics are stored in PostgreSQL and can be used to populate the eXtremeDB databases in the event of system shutdown and restart. eXtremeDB manages real-time attributes, updating them as new data arrives from the PLC, and periodically flushing this information to PostgreSQL.

“Features of the eXtremeDB database, including its in-memory architecture, native C/C++ interface and highly efficient indexing, are critical in delivering the performance BISMARC demands in its tag database,” Penkov said. “This level of responsiveness is not attainable with a traditional relational DBMS that stores all data to disk and requires use of the high-level SQL database interface. We were pleased to discover eXtremeDB and its highly optimized features.”

Before selecting McObject’s database, the BIS team considered writing data management code in-house. Disadvantages of this approach included increased time-to-market, and the extensive debugging and QA inherent in a ‘homegrown’ database system. BIS likely saved six months of development time by opting for eXtremeDB, and benefits from McObject’s ongoing support of the product, Penkov said.

Other key eXtremeDB features for BISMARC included its support for multiple data types, which enable a highly efficient data design, and its portability. While BISMARC’s Linux support meets the need of most European nuclear power producers, BIS may one day wish to support additional embedded platforms, or offer a 64-bit edition. eXtremeDB runs on platforms including all major server and real-time operating systems (RTOSs), and can even run without an OS in "bare bones boards" configurations. To simplify porting, its design minimizes reliance on OS-specific features.

“Many applications, particularly in fields such as real-time industrial control and safety-critical systems, cannot tolerate the latency inherent in traditional DBMSs. eXtremeDB was designed precisely to deliver the speed and predictability needed for control systems, and the product is enjoying increased adoption in applications for energy producers. We’re pleased that eXtremeDB is playing a key role in enabling BIS to meet its customers’ needs,” said Steve Graves, McObject CEO and co-founder.

About Baltic Information Systems

Baltic Information Systems is focused on development of safety-related IT systems for nuclear power plants. Since 2000, BIS has led innovative projects in this field, typically in Lithuania (where it is based), the EU, and former Soviet Union. Its BISMARC process control and monitoring SCADA system may be configured to most plant monitoring tasks.

www.bis.lt

About McObject

Founded by embedded database and real-time systems experts, McObject offers data management technology that makes applications and devices smarter, more reliable and more cost-effective to develop and maintain. McObject counts among its customers industry leaders such BAE Systems, Siemens, Phillips, EADS, JVC, Tyco Thermal Controls, F5 Networks, CA, Motorola and Boeing. McObject is based in Issaquah, WA.

www.mcobject.com

McObject provides this illustration showing the BISMARC operator interface at the Smolensk installation with more information at www.mcobject.com/january5/2011.

- Edited by Mark T. Hoske, CFE Media, Control Engineering, www.controleng.com

 

 

 

 

Regards,

 

 

 

Ted Kenney

Marketing Director

McObject

22525 SE 64th Pl., Suite 302

Issaquah, WA USA 98027

Ph. 425 888-8505, ext. 213

www.mcobject.com

www.facebook.com/McObject



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me