Designing high-performance buildings using 189.1

ASHRAE Standard 189.1 sets the standard for the total building sustainability package.

11/20/2013


Industry standards set by ASHRAE and Illuminating Engineering Society (IES) have been integrated into the U.S. Green Building Council (USGBC) LEED baseline references since the original development of the LEED rating system.

In the 15 years since the USGBC introduced the pilot version of the LEED rating system, these three organizations have continuously worked together to keep the standards moving in the direction of performance and efficiency. At the same time, technology, design, and construction have evolved in response to these changes. 

In 2009, when ASHRAE, IES, and USGBC introduced Standard 189.1: Standard for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings, it was a significant step, marking the first time that high-performance green building characteristics had been developed as code-enforceable language. ASHRAE has since released Standard 189.1-2011, which supersedes the original version and is listed as an alternative compliance path in the 2012 International Green Construction Code (IgCC). 

Unless a jurisdiction in which you regularly engineer and design buildings has adopted or is considering adopting Standard 189.1 or IgCC as part of its code requirements for permit and occupancy, Standard 189.1 may not have an impact on your current projects. Regardless, the fact that it is now an option for jurisdictions to consider makes it important for building design industry professionals to have a basic understanding of what it entails. It is equally important to monitor the code adoption plans and procedures of the jurisdictions where you provide service to make sure you have the chance to review and comment on proposed changes.

As a standard, 189.1-2011 provides guidelines and minimum requirements for the design of high-performance green buildings except low-rise residential buildings. For the purposes of this overview, the standard will be reviewed in its native form of ASHRAE Standard 189.1.   

It is important to remember that compared to ASHRAE Standard 90.1, 189.1 covers many aspects of construction beyond energy use. Standard 189.1 includes provisions for site sustainability, water efficiency, indoor environmental quality, materials and resources, and commissioning in addition to energy use. As jurisdictions begin to adopt 189.1 either directly or through the IgCC, these sections will have to be considered against existing regional agencies, departments, and regulations. For example, most jurisdictions have zoning laws on the books that may contradict the site development requirements of 189.1. 

Standard 189.1 is divided into 11 sections and is supported by nine appendices. Sections one through four cover the purpose, scope, definitions of key terms, and administration of the standard; Section 11 contains a listing of all other standards referenced in the document, detailing the location of the reference and its responsible governing body. 

If you have worked with LEED, the remaining sections are broken into categories that will look familiar: Site Sustainability, Water Use Efficiency, Energy Efficiency, Indoor Environmental Quality, Impact on Atmosphere, Materials and Resources, and Construction Plans for Operation. 

Each section has a collection of mandatory provisions that must be met in order to comply, and with the exception of Construction and Plans for Operation, each section offers both prescriptive and performance options for compliance. Construction and Plans for Operation includes only mandatory provisions.

Section 5 - Site Sustainability: This section covers preferred building sites (greenfield versus brownfield), roofs and site hardscape, light pollution, and plant species located on the project site with the intent of improving site selection and development, minimizing heat island impact, and reducing light pollution. 

Section 6 - Water Use Reduction: All site and building-related potable and non-potable water consumption, including outdoor water use for irrigation and irrigation system design and controls, is covered in this section. Maximum allowable flow rates are provided for various types of plumbing fixtures. In addition, water-consuming appliances, mechanical systems, medical systems, and roof irrigation are addressed. 

Section 7 - Energy Efficiency: This section outlines requirements for building energy efficiency, on-site renewable energy systems, and energy monitoring, and largely defers to the requirements of ASHRAE Standard 90.1. Provisions that go beyond the performance requirements of 90.1 include exterior wall and roof performance; fenestration performance, area, and orientation; HVAC system efficiency; and lighting power density. In addition to the systems covered by Standard 90.1, this section includes requirements for energy consumption metering, provisions for on-site renewable energy, and horizontal and vertical projections on the exterior. When using the performance option, an energy cost comparison alone is not allowed. The engineer must also demonstrate that the CO2 produced by operating the model building will not exceed that of a baseline model. 

Section 8 - Indoor Environmental Quality: In this section, you will find requirements for eliminating environmental tobacco smoke, preventing particulate contamination from entering the building (through walk-off mats and mechanical filtration), monitoring ventilation rates, reducing material volatile organic compound (VOC) levels, and daylighting provisions. The section also contains acoustical control requirements that focus on limiting sound transmission between different areas. The first acoustical control requires sound attenuation between the inside of the building and the outdoors when located near high-noise sources (e.g., expressways and airports). This is mandated in the form of wall, roof, and fenestration sound transmission class (STC) ratings. Interior sound (between spaces) is controlled through STC-rated partitions between dwelling units, and between assembly areas, such as conference rooms, and other use areas.

Section 9 - Impact on the Atmosphere, Materials, and Resources: Provisions for the handling of materials range from sourcing (location, biobased, and wood certification) to end of life (waste diversion, recycling, and total waste amount for a construction project). Ozone-depleting characteristics of components such as refrigerants are addressed in this section. As an alternative to the prescriptive path for materials, a lifecycle assessment (LCA) can be performed comparing at least two alternative constructions covering the material components addressed by the prescriptive path and compliant with Sections 6, 7, and 8 and the mandatory requirements of Section 9. Performing an LCA for Atmosphere, Materials, and Resources is analogous to performing an energy model for the building energy efficiency. That is, the LCA provides designers with more freedom to exceed the performance requirements of the standard by not being limited to the prescriptive path. In the LCA, the accepted alternative must demonstrate a 5% improvement over the prescriptive building alternate in at least two of the impact categories: land use, resource use, climate change, ozone layer depletion, human health effects, ecotoxicity, smog, acidification, and eutrophication. The section references ISO Standard 14044 for performing the LCA. 

Section 10 - Construction and Plans for Operation: All provisions listed in this section are mandatory. Construction primarily covers construction activities and the commissioning effort and includes controlling moisture on the construction site, limiting vehicle idling, erosion and sediment control, and indoor air quality control. The commissioning portion outlines the commissioning process and identifies what systems must be commissioned. Plans for Operation tackles post-occupancy activities required to keep the building operating as it was designed throughout the building life. There are six main systems that are identified to be commissioned: mechanical systems, lighting systems, fenestration control systems (automatic shades and dynamic glazing), renewable energy systems, water measurement devices, and energy measurement devices. 

Plans for Operation starts with developing a high-performance building operation plan. In addition to tracking and recording energy and water use, site sustainability must be maintained through preservation of site vegetation. Indoor environmental quality is to be maintained through outdoor airflow measurement and indoor air quality maintenance. Finally, a maintenance plan must be developed and implemented that covers the building mechanical, electrical, and plumbing systems. This section is important because as the building systems become more complex to reduce energy use and improve indoor environmental quality, it is necessary that these systems function as they were designed. Otherwise, system performance will suffer and with it the energy use will increase, indoor environmental quality will decrease, and there will be a negative impact on the surrounding environment.


<< First < Previous Page 1 Page 2 Next > Last >>

Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me