Designing efficient office buildings with visual appeal: Electrical/lighting/power

Office buildings can be highly complex, with complicated features and advanced technology regarding electrical, lighting and power. Experienced engineers share advice on how to handle these structures and identify trends impacting such structures now and in the future.

02/08/2018


Jason Gerke Mechanical & Plumbing Group Manager, GRAEF, Milwaukee. Courtesy: GRAEFJames Hansen, PE, BEMP, LEED AP, Principal and Senior Mechanical Engineer, GHT Ltd., Arlington, Va. Courtesy: GHT Ltd.Tyler Jensen, PE, LEED AP, Senior Associate, Environmental Systems Design, Inc. Chicago. Courtesy: ESDJohn Yoon, PE, LEED AP, Lead Electrical Engineer, McGuire Engineers Inc., Chicago. Courtesy: McGuire Engineers Inc.

Respondents



The 2112 Pennsylvania Avenue project is an 11-story, 250,000-sq-ft trophy Class A commercial office building in Washington, D.C. GHT Ltd. provided MEP engineering design, energy modeling, and LEED documentation services on the project. Features include 1st-floor retail, a fitness center, and other amenities. Courtesy: SkanskaCSE: Describe metering or submetering in an office building. What did it include, and what best practices did you include?

Yoon: You need to have a clear idea of what functions are required by the client when designing electrical metering systems. Is it tenant-revenue recovery? LEED measurement and verification compliance? Power-quality monitoring or load management? Or maybe a combination of these? The temptation is to over-specify. Oftentimes, it may only seem like an incremental increase in the upfront hardware cost to add functionality, but it can dramatically increase the total cost of ownership.

Although some metering manufacturers promote their products as proverbial Swiss army knives that can do everything, there are usually hidden costs that affect the total cost of ownership. Taking advantage of increased functionality generally means going beyond simple hardware specifications to include additional stand-alone software/licensing, building automation system/BMS point programming, WAN/LAN access, etc. While the metering hardware may have a useful service life of 20+ years, what about these associated systems?

CSE: Are you seeing more smart grid or microgrid aspects on office building projects? If so, how have you served these needs? Are there any issues unique to these projects?

Yoon: While the local regional public utility companies are pushing hard for deploying new microgrids, we haven't seen much in the way of implementing them in the Midwest. In general, the primary barrier is the availability of funding for new distributed generation and storage. While the U.S. Department of Energy offers grants as part of their grid-modernization initiative, the overwhelming majority of the funding still has to come from the local ratepayers. For example, in Illinois, the utility company serving the northern half of the state has attempted to attach funding provisions for microgrid pilot projects to rate case legislation. Those attempts have so far failed due to opposing lobbying efforts from various consumer advocate groups.

While microgrids offer the potential of improved electrical-grid security and resiliency, it's hard to dispel the perception that these programs amount to corporate welfare by providing public funding so that a utility company can experiment with new technologies-technologies that can improve their profitability and circumvent laws that make a clear legal separation between the deregulated side of the business (power generation) and the regulated local public utility monopoly (distribution). Whereas the local utilities were often required to divest themselves of any power plants when deregulation happened, what happens when their new microgrids incorporate wholly owned distributed-generation assets?

Ultimately, the public good is served by having reliable and resilient electrical distribution infrastructure. There are various ongoing concerns: cybersecurity, the ability of utility companies to support their existing infrastructure with the overall decline in electrical usage/revenue, etc. The primary question is how utility companies in a regulated environment can reinvent themselves to remain economically viable and still serve the public good.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me