Russelectric, A Siemens Business
Products
Cogeneration systems for combined heat and power applications
Russelectric, a Siemens Business, is a manufacturer of automatic transfer switches and power control systems, who manufactures UL-listed cogeneration systems for combined heat and power (CHP) applications in which the generator sets are run to serve the connected load and heat is also recovered for other uses. Designed and built for mission critical facilities such as healthcare, research and development and campus facilities, Russelectric cogeneration systems are designed to provide maximum protection for operators and maintenance personnel and to minimize the danger of operator error. All Russelectric cogeneration systems are UL listed, offer programmable logic controller (PLC) system controls, and are supervisory control and data acquisition (SCADA)-capable. They feature utility/generator and other power assets paralleling control, and provide active synchronization and soft loading. Systems use a utility-approved interconnecting protective relay system. Russelectric cogeneration power control switchgear may have additional controls and monitoring to optimize heat recovery.
Prime Power Systems
Russelectric, A Siemens Business, a leading manufacturer of power control systems and automatic transfer switches, offers its Prime Power Systems, which are used for automatic operation of on-site power generators to serve a facility’s entire load. The Prime Power Systems are used as the primary source of power to a facility. Generator paralleling controls provide active synchronization and soft loading control of the engine generators based on load demand. All Russelectric Prime Power systems are UL listed, offer programmable logic controller (PLC) system controls, and are supervisory control and data acquisition (SCADA)-capable. In prime power applications, engine generators are run in response to the connected load.
External Manual Operator (E.M.O.) on Automatic Transfer Switches
The External Manual Operator (E.M.O.), a standard feature of the Russelectric RTS-03 Series and RTS-30 Series of open-transition automatic transfer switches, the most rugged and complete line of 480 VAC 30-cycle and 3-cycle UL tested switches available in the market today. The unique E.M.O feature enables easy, safe, and quick manual transfer with the door fully closed, significantly reducing downtime and the risk of arc flash injuries. With the E.M.O, the manual transfer process is easier and faster for both the preferred and the alternative power sources, and no special procedures are required to ensure the system is de-energized during the transfer operation. That means less downtime because the cabinet door remains closed. The E.M.O utilizes the same Russelectric transfer mechanism as the automatic electrical operator, a design proven to provide exceptional safety and durability.
RTS-30 Series of Automatic Transfer Switches
Russelectric RTS-30 Series of automatic transfer switches for hospitals, healthcare facilities and other critical facilities, the most rugged and complete line of 480 VAC 30-cycle and 3-cycle UL tested switches available in the market today. All Russelectric RTS-30 Series automatic transfer switches have been fully tested, listed, and labeled for 30-cycle and 3-cycle closing and withstand ratings under UL-1008. In addition, the RTS-30 meets all requirements for legally required standby systems for selective coordination. The RTS-30 Series of transfer switches feature preloaded springs and an over-center mechanism driven by an electric operator for opening and closing the power contacts.
Emergency Power System for Wastewater Treatment Plants
Russelectric offers its robust and reliable Emergency Power System which provides backup power during a utility power loss. The paralleling switchgear systems offer redundant programmable logic controller (PLC) controls and manual backup capability. Trusted by the largest critical facilities in the world, the Russelectric Emergency Power System has been used by wastewater treatment plants.Complete systems are custom designed and fully manufactured by Russelectric.