Belimo

The Belimo Group is the global market leader in the development, production, and sales of field devices for the energy-efficient control of heating, ventilation, and air-conditioning systems. The focus of our core business is on damper actuators, control valves, sensors, and meters. Constant focus on market and customer needs makes us a partner that offers our customers unprecedented added value.In 2022, the Company reported sales of CHF 847 million and over 2,200 employees. Information about the Company and its products is available at www.belimo.com. The shares of BELIMO Holding AG have been traded on the SIX Swiss Exchange since 1995 (BEAN).

Articles

RetroFIT+ offers online resources, including a product selection tool, as well as personal support that provide quick and easy access to HVAC replacement solutions for actuators, valves and sensors. Courtesy: Belimo
HVAC/R and Mechanical September 18, 2023

HVAC retrofit program launched

Belimo's RetroFIT+ offers ways to upgrade existing HVAC systems for enhanced comfort and energy efficiency.

By Belimo
Courtesy: CFE Media and Technology
HVAC/R and Mechanical August 16, 2023

Event for retrofitting and energy efficiency benefits for HVAC professionals announced

Belimo's online event for HVAC professionals on September 7 emphasizes the impact retrofitting can have on energy efficiency.

By Belimo
February 28, 2017

Advanced butterfly valve

Belimo's advanced butterfly valve comes with the PKR electronic fail-safe actuator for enhanced control.

By Belimo
All Articles

Products

Fire and Life Safety November 16, 2023

22HL-50 Leak Detector Sensor

Belimo's 22HL-50 Leak Detector Sensor is engineered to detect liquid leaks in containers, drain pans, false floors, suspended ceilings and rooms. It features a single relay contact that can be wired to alert a control system, trigger an alarm, or close a valve to halt the flow of liquid. It has easy to read green/red “traffic light” status LEDs for clear visual indication of leaks.

Belimo
HVAC/R and Mechanical September 28, 2022

Press Fit Valve Assemblies

Belimo releases a new press fit valve assembly series Danbury, CT, September 28, 2022 – Belimo Americas announces the release of QCV (pressure dependent) and PIQCV (pressure independent) ZoneTight zone valves with new press fit connections for fast, consistent, and reliable installation. Zone valve assemblies are designed and engineered for maximum efficiency in tight spaces and are suited for commercial buildings where higher close-off and adaptable flow are desired. - Assemblies accommodate chilled or hot water, 60% glycol, and a body pressure rating of 250 psi. - Zero leakage ball valve design eliminates energy losses and is resistant to clogging. - Available pressure dependent range 1/2 to 1" and pressure independent 1/2 - 3/4". - Lower power consumption up to 95% less than conventional zone valves. - Field adjustable flow to meet your design requirements. "For OEMs and contractors, these new zone valve assemblies with press fit connection provide a fast installation and energy-efficient solution. Unlike any other zone valve on the market today, the valves are field adjustable, allowing you to adjust the pressure to suit your needs," states Russ Brown, Product Manager. Typical applications include unit ventilators, fan coil units, VAV reheat coils, fin tubes, and radiant panels.

Belimo
HVAC/R and Mechanical December 2, 2022

22PDP Sensors

Belimo's new 22DPD sensors for wet-to-wet differential pressure measurement utilizing remote sensors in HVAC systems  On December 2, Belimo released new 22PDP-585 and 22PDP-588 active sensors (4...20 mA / 0...5 V / 0...10 V) for wet-to-wet differential pressure measurement utilizing remote sensors in HVAC systems. The sensors are suitable for water and water-glycol mixtures. The 22PDP reduces installation time and material costs with external sensors by connecting the high and low side sensors at the measurement point. The hinged cover and spring-loaded terminal block save wiring time and ensure reliable contact.

Belimo
All Products