Port of Long Beach, Middle Harbor Redevelopment
System overhaul: Port of Long Beach, Middle Harbor Redevelopment; P2S Engineering
Project name: Port of Long Beach, Middle Harbor Redevelopment
Location: Long Beach, Calif.
Firm name: P2S Engineering
Project type, building type: System overhaul, manufacturing
Project duration: 6 years
Project completion date: June 9, 2012
Project budget for mechanical, electrical, plumbing, fire protection engineering only: $70 million
Engineering challenges
The Port’s middle harbor container shipping terminals were old, outdated, and designed for a past era of containerized shipping. To improve efficiency and meet current 21st century environmental standards, they had to be updated. This would allow the Port of Long Beach not only the opportunity to utilize new technologies, but also infrastructure upgrades that would improve the environment. As a result, once completed, the power infrastructure will have the capacity to fully support not only typical terminal needs (medium-voltage quay cranes, site lighting, and building distribution), but also greener port technologies such as shore-to-ship power and electrified rail-mounted gantry cranes in the container yard.
Solutions
P2S designed a reliable distribution system to serve present and future needs for the Middle Harbor. The completed mega-terminal will be served by a 112 MVA, 66-12 kV substation that will be constructed in stages over the next 10 years. The terminal also includes a 12 kV intermodal yard substation; (3) 6.6 kV shore power substations; (10) 480 V reefer substations; site distribution to facilitate power and communications to medium-voltage quay and stacker cranes, shore power outlets, reefer outlets, terminal site lighting, and buildings; and a state-of-the-art energy and power management solution for managing the increased demands of the electrified terminal. P2S is also advancing and standardizing shore-to-ship power solutions by leading the development of an international IEC/ISO/IEEE standard for shore-to-ship power. This ensures that the shore-to-ship power system at the Middle Harbor is state-of-the-art. It will also serve as an example for other terminals nationwide to follow.
Do you have experience and expertise with the topics mentioned in this content? You should consider contributing to our WTWH Media editorial team and getting the recognition you and your company deserve. Click here to start this process.