Wireless instrumentation helps pipeline operator with diagnostics

Atlas Pipeline – Westex improves production efficiency at gas processing facility, joining old equipment to new control room.

10/20/2010


When Atlas Pipeline – Westex wanted to bring data from an old plant into its new control room, the cost of adding all the necessary wiring to do the job threatened to kill the project. But there was another solution.

“Wireless was our only way to do this project," said Wayne Wasson of Atlas. "Without it we would have spent three times as much.”

Atlas used Emerson Process Management’s Smart Wireless technology and saved an estimated $725,000 in installation costs. The result has been improved production efficiency at its Benedum natural gas processing facility near Midkiff, TX. The self-organizing IEC 62591 (WirelessHART) network connects a new plant with an older unit in the same facility. Pulling data from the old plant into the new plant’s control room using conventional wiring was not financially feasible because of the distance and obstacles between the two plants.

The wireless network includes 99 of Emerson's Rosemount wireless temperature, pressure, level, and discrete-input transmitters that communicate with three Smart Wireless Gateways to collect real-time data from gas processing and storage tanks, cooling towers, and compressors. The majority of the wireless devices replaced local indicators in the old plant, while others measure pressure along pipes between the two plants and tank level in the new plant.

Data from the wireless network is integrated into the plant’s DeltaV digital automation system, which monitors and controls critical plant processes. Atlas operators also use AMS Suite: Intelligent Device Manager predictive maintenance software to actively manage key field devices in both plants, including Fisher valves. Predictive diagnostics provided through AMS Suite have enabled Atlas to eliminate operator rounds to the old plant, saving multiple trips per day.

“The application gave us a centralized location to view our total plant process,” said Wasson. “Our operators do not have to make rounds to learn about potential problems. They can more efficiently operate the plant by seeing changes and problems when they occur. Overall installation was easy and seamless and took about a day to have them all communicating and showing up in the DeltaV system.”

www.EmersonProcess.com/SmartWireless

Edited by Peter Welander, pwelander(at)cfemedia.com

Also read Wireless technology moves into broader process control applications



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.