Wireless device integration specification released

The Fieldbus Foundation's final specification for ISA100.11a Device Integration incorporates network protocols into its for Remote Operations Management (ROM) infrastructure.

01/09/2014


Foundation Fieldbus expands it wireless capabilities that work with ISA100.11a protocol devices. Courtesy: Control EngineeringThe Fieldbus Foundation has released the final specification for integration of ISA100.11a wireless field devices into its Foundation for Remote Operations Management (ROM) technology. This development is said to allow automation end users to employ multiple wired and wireless protocols for greater flexibility and expandability. The Foundation specification means that end users can manage ISA100.11a wireless devices just like Foundation fieldbus devices within the Foundation fieldbus infrastructure. 

Foundation for ROM will extend the capabilities of Foundation fieldbus to many wired and wireless devices installed in some of the world's harshest and most remote locations, according to sources at the Fieldbus Foundation. This includes the implementation of a true predictive and proactive maintenance strategy for remote assets that could not previously support one. Foundation for ROM provides a unified digital infrastructure for asset management in applications ranging from tank farms and terminals to pipelines, offshore platforms, and even original equipment manufacturer (OEM) skids.

With this release, the Fieldbus Foundation has finalized the remote I/O, wired HART and WirelessHART, and ISA100.11a portions of the Foundation for ROM specification. The technology integrates these protocols, along with H1 fieldbus, into the Foundation fieldbus managed infrastructure.

Specifications for Modbus communications are in development that will enable Modbus devices, such as wellhead flow meters and submersible pump controllers to be integrated in a similar way.

The new specification includes parameters for ISA100.11a transducer blocks, providing the block application objects into which ISA100.11a variables may be mapped for access by other fieldbus devices. The transducer blocks also provide a mechanism to pass data to and from ISA100.11a devices directly from configuration or asset management hosts.

The Fieldbus Foundation's ROM infrastructure provides a single source for data management, diagnostics, alarms and alerts, data quality control, control-in-the-field capability, and object-oriented block structure. Its High Speed Ethernet (HSE) TCP/IP protocol enables remote operations information to be communicated to the control system over any wired or wireless backhaul network using the architecture model developed in a joint collaboration between the Fieldbus Foundation and the International Society for Automation (ISA) under the ISA100.15 Wireless Backhaul Networks Working Group.

To ensure interoperability, Foundation for ROM devices from multiple suppliers utilize Electronic Device Description Language (EDDL) and interoperability testing. This is essential to improve integration of critical functional areas, including machinery health monitoring, safety interlocks, fire & gas detection systems, and video surveillance.

Fieldbus Foundation

www.fieldbus.org 

- Edited by CFE Media. See more Control Engineering networking stories.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me