William Koffel joins editorial advisory board

William Koffel, PE, FSFPE, has joined the Consulting-Specifying Engineer editorial advisory board.

07/01/2014


William Koffel. Courtesy: Koffel Associates.Bill Koffel is president of Koffel Associates, Columbia, Md., a fire protection engineering design/consulting firm, and is recognized as an expert in the fire protection/life safety aspects of codes and standards. Headquartered in the Baltimore-Washington metropolitan area, the firm provides consulting, engineering design and construction administration, codes and standards development, seminar development/training, product testing/evaluation/representation, and litigation support to public/private clients worldwide. Koffel remains active in the development process of the industry’s governing codes, standards, and design guidelines including ICC, NFPA, SFPE, and UL. A former code official with the Maryland State Fire Marshal’s Office, he is a past president of the Society of Fire Protection Engineers.

 

 

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me