Westlake Reed Leskosky: Smithsonian Institution Renwick Gallery

Westlake Reed Leskosky: Smithsonian Institution Renwick Gallery

08/11/2016


Main attic mechanical room. Courtesy: Kevin ReevesEngineering firm: Westlake Reed Leskosky

2016 MEP Giants rank: 86

Project: Smithsonian Institution Renwick Gallery

Location: Washington, D.C.

Building type: Museum

Project type: Existing building retrofit

Engineering services: Automation, controls; electrical, power; HVAC, mechanical; lighting; energy, sustainability; plumbing, piping

Project timeline: March 2012 to November 2015

MEP/FP budget: $12 million

Grand stair. Courtesy: Kevin ReevesChallenges

The building was originally completed in the 1870s and is listed on the National Register of Historic Places. It was the first purpose-built art museum in the U.S. and became a Smithsonian Museum in the early 1970s. The engineering approach required sensitivity to the historic nature of the building within very tight spatial constraints. Systems are required to maintain appropriate environmental control for a varied collection (ASHRAE Class A), coupled with high visitor traffic.

Solutions

The team worked in a highly integrated manner to allow replacement systems to better use space within the existing structure without any modifications to the existing mass of the building. The team helped pioneer a new type of LED source to allow the gallery lighting power density to operate at approximately 1 W/sq ft while still providing sufficient beam control for highlighting objects from sources located relatively far away. The project has performed approximately 50% more efficiently, even with visitor attendance approximately four times higher than in 2012, prior to renovation.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me