Water-cooled centrifugal chiller

The YORK YK-EP uses a OptiSpeed variable speed drive, which can accept medium or high voltage power, trimming energy consumption.

04/08/2016


The YORK YK-EP uses a OptiSpeed variable speed drive, which can accept medium or high voltage power, trimming energy consumption. Courtesy: Johnson ControlsJohnson Controls' YORK YK-EP Efficiency Plus water-cooled centrifugal chiller uses a patent-pending mechanical compression economizer cycle to boost performance over conventional chiller platforms. The YK-EP uses a OptiSpeed variable speed drive, which can accept medium- or high-voltage power, trimming energy consumption. The chiller is able to operate with 50°F low entering condenser water temperature (ECWT). In facilities with multiple YK-EP chillers, energy savings can be accomplished with series-counter flow arrangement. This reduces the compressor work needed on each chiller, cutting system energy use at design conditions. The YK-EP chiller has capacity of 2,500 to 3,500 tons and is suited for large tonnage applications including district cooling or large central plants such as universities and airports.

Johnson Controls

www.johnsoncontrols.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me