SEARCH Archives
Loading
Sponsored by:

USB interface module offers high-performance solution for industrial communication

Molex SST DN4 DeviceNet design provides a compact, reliable and cost-effective USB alternative to the DN4 Network Interface Card (NIC).

06/29/2011


Molex Incorporated has introduced the SST DN4 DeviceNet (a device-level network from ODVA Inc.) USB interface module to complement its range of SST DN4 DeviceNet Network Interface Cards (NICs). The SST DN4 DeviceNet USB interface module provides industrial OEMs and end-users with a compact, high-performance DeviceNet interface for PC communication that maximizes performance in control and monitoring applications.

“The SST DN4 DeviceNet USB interface module design is a functional replacement for DeviceNet Pro PC Card (PCMCIA) cards,” explains Michael Frayne, global product manager, Molex. “This provides backward compatibility with DeviceNet Pro (DNP) cards for legacy system connections.”

Like the SST DN4 NICs, the USB interface module uses an enhanced FPGA design with a lower component count, resulting in an extended product lifecycle and higher reliability. Ideal for real-time control and data acquisition applications, which range from PC control and HMI/SCADA systems, network configuration, troubleshooting and diagnostic tools, the Molex DN4 USB interface module provides industrial OEMs and end-users with a more reliable and cost-effective solution for industrial communication.

Simultaneous execution of Group 2 Client (Master) and Server (Slave) operations allows the OEM and end-user to implement control schemes where all capabilities may be required. Suitable for any DeviceNet control scheme, the DN4 supports poll, strobe, change-of-state (COS) and cyclic input/output messaging. The QuickConnect capability of the USB interface module in Client (master) mode allows the devices to be accessed on power-up in less than 500 milliseconds.

The DN4 USB interface module provides multiple network support for all standard DeviceNet baud rates (125, 250 and 500k baud), as well as use in CAN (Control Area Network) networks (2A, up to 1 Mbps), reducing OEM inventory. The USB interface module from Molex is USB high-speed 2.0 compatible and is offered with a standard USB Type B receptacle.

The DN4 USB interface module is designed and conformance tested in accordance to ODVA standards (Volume 3, v 1.8).

www.molex.com/link/dn4.html Molex Inc.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.