SEARCH Archives
Loading
Sponsored by:

Universal mounting kit

Electro Static Technology's Split uKIT is for HVAC service contractors and plant maintenance departments.

02/17/2012


Electro Static Technology’s Split uKIT is ideal for HVAC service contractors and plant maintenance departments. Designed to accommodate slingers, shaft shoulders, and other end bell protrusions, the kit comes with a split AEGIS ring, the halves of which are held together with a hinge. This hinge design allows the split AEGIS ring to be opened on one side, then closed and fastened together with built-in adhesive-backed aluminum tabs, providing rigidity to the assembled ring. AEGIS rings prevent electrical bearing damage, costly motor repairs/replacements, and downtime by safely channeling VFD-induced bearing currents to ground. Continuous circumferential rows of conductive microfibers are embedded securely in the ring’s FiberLock channel, completely surrounding the motor shaft and providing millions of discharge points for harmful shaft currents. This design creates the path of least resistance that effectively diverts these currents away from bearings to ground. The microfibers are specially engineered for conductivity and flexibility to minimize wear and prevent breakage.

www.est-aegis.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.