Ultra-low energy radio for wireless sensor networks, environmental monitoring, smart metering

Toumaz's TZ1053 Telran ultra-low energy wireless radio offers low-power continuous use radio in sub-1GHz ISM band.

03/30/2011


Toumaz, a provider of ultra-low power wireless telemetry technologies for medical monitoring and internet-connected consumer devices, has announced the launch of TZ1053 Telran – an ultra-low energy (ULE) radio for wireless sensor networks, remote controls, green energy solutions, smart meters, and environmental monitoring. Built on Toumaz’s proprietary AMx Mixed Signal technology, the high-performance sub-1GHz radio SoC offers 1V operation using a single button cell battery and consumes less than 3mW continuous use power consumption.

Commenting on the Telran launch, Toumaz CEO Professor Chris Toumazou said: “With this important addition to our ‘Connected Consumer’ portfolio, we are harnessing our strengths in ultra-low energy wireless healthcare to create solutions for high-volume consumer markets. Telran is uniquely placed to support the development of a range of new ultra-low energy wireless applications, and we are very excited by the product opportunities that we will be enabling for our customers with today’s launch.”

The TZ1053 Telran uses AMx state-of-the-art ultra-low energy technology to deliver much longer life from low voltage battery-based systems for customers developing ultra-low energy applications – without compromising on performance. Designed with ease of use in mind, the Telran contains an enhanced 8051 running Toumaz’s Nanopower Sensor Protocol (NSP) allowing developers to program and control the Telran device easily with high level commands either over a standard interface eg UART or “over the air.” Target applications include the development of two-way communication remote controls for consumer electronic devices; wireless sensor networks based on Telran sensor nodes and base stations; environment monitoring and room temperature control; remote controls and toys/games; and smart metering, using Telran wireless sensor networks to connect multiple meters for the two-way transmission of status data and firmware upgrades.

Highlight features of the Telran IC include:

  • Fully integrated SoC comprising transceiver, baseband, embedded microprocessor and control logic
  • Ease of development – no compilers or specialist programming investment required
  • Simple over-the-air programming and reconfiguration
  • Quick and efficient customization using application profiles
  • Support for networking and communication modes including P2P (Point to Point), star network (up to 8 sensor nodes) and base station-to-base station communication
  • Data rate of 50 kbps with a range greater than 100m line of sight using a high gain antenna, or 20m from a PCB or chip antenna in a body-worn environment.
  • Ability to directly connect SPI/I2C sensors

www.toumaz.com

Toumaz

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me