TTEthernet: Time-triggered services deliver synchronous Ethernet

TTEthernet provides a set of time-triggered services implemented on top of standard IEEE 802.3 Ethernet.

08/18/2010


 

TTEthernet enables synchronous network services.

TTEthernet provides a set of time-triggered services implemented on top of standard IEEE 802.3 Ethernet, according to TTTech Computertechnik AG, a supplier of field of time-triggered computer systems. Those services are designed to enable design of synchronous, highly dependable embedded computing and networking, capable of tolerating multiple faults. Other real-time Ethernet variants impose significant restrictions upon, or modify, Ethernet to achieve desired real-time performance. This is not the case with TTEthernet.

-----------------------------------------------------------------------------

 

40 Under 40 – Control Engineering: Know someone working in automation under age 40 in need of some recognition? See the 40 Under 40 awards.

-----------------------------------------------------------------------------

It’s most important aspect is that the hard real-time time-triggered communication services do not make obsolete or modify any of Ethernet's properties, so the network can be flexibly shared by hard real-time and standard LAN applications.   TTEthernet networks provide a fault-tolerant time base. A distributed clock makes the exchange of timing data throughout the system is redundant. This is the key to reliable operation with continuous time base under multiple or complex faults, which is essential for design of critical and certifiable systems.

Robustly partitioned multimedia data streams, storage, critical control data and standard LAN messages can operate in one network without congestion or unintended interactions. This allows flexible use of Ethernet in a variety of time-, safety-, and mission-critical applications, with full control of latency and jitter.   Standardization of TTEthernet is done within the SAE organization and driven by the TTA-Group.

Key services are described in the SAE AS6802 “Time-Triggered Ethernet” standard. Today, TTEthernet is used for highly critical aerospace and industrial applications. The graphic was provided by TTTech Computertechnik.

Also read: High Performance Industrial Networks.

TTTech Computertechnik AG www.tttech.com

See the Control Engineering Industrial Networks Channel at www.controleng.com/networks



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.