Transfer switches

Generac Power Systems' Power Series transfer switches (PSTS) and the ATC-900 transfer switch control can be used with Generac's industrial standby generator line.

05/15/2015


Generac Power Systems' Power Series transfer switches (PSTS) can be used with Generac's industrial standby generator line.Generac Power Systems' Power Series transfer switches (PSTS) and the ATC-900 transfer switch control can be used with Generac's industrial standby generator line. The ATC-900 transfer switch control offers supervisory and programming capabilities and includes 14 different platforms with capabilities up to 5,000 amp. It features open and delayed transition on 3-cycle switches, and short-time ratings. It includes a double-throw interlock transfer mechanism. Advanced diagnostics allow the controller to capture and record up to 450 real time-stamped events. It's equipped with 20 inputs and outputs, and has a variety of monitoring and control functions, such as remote load testing and selective load shedding. Operating parameters can be set using a computer, or can be saved to a jump drive and uploaded directly to the control.

Generac Industrial Power

www.generac.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me