Top-down strategies innovate mechatronic machine engineering

Original equipment manufacturers need to manage the design process and recognize mechatronic trends to stay ahead of the technology curve. By developing a portfolio of mechanical, electrical, and software modules, it becomes easier to quickly assemble “custom” machines to meet customer requests. Mechatronics is the convergence of power, electronics, and mechanical systems, including embedded software and hardware in engineering design.

By Tom Jensen February 11, 2014

Mechatronics is the interdisciplinary collaboration of power, electronics, and mechanical systems, including embedded software and hardware—or, more simply stated, the convergence of engineering disciplines. Mechatronic engineering improves component integration, yielding smaller machines that perform better and cost less to build and support. Developing a mechatronic team demands top-down strategies and a synergistic view of engineering design tools, drive systems, and control design.

Before a mechatronics approach is in place, many machine builders’ R&D efforts often begin at the point of sale. A traditional engineering approach taps electrical, mechanical, and software engineers, each bringing to the table a specific skill set. A mechanical engineer may rework an existing machine design and remit it to the electrical engineer, who then fashions a control panel out of standard technology. Then a software engineer is tasked with executing the project. Delays occur anytime incongruencies exist between the machine concept, component selection, mechanical design, electrical design, program methodology, and even the end user’s intended purpose for the machine. Out of time, the software engineer might be expected to patch together a mechanical hardware concept with a misaligned electrical hardware concept, without even fully understanding why they don’t work together.

Depart from traditional engineering

Mechatronics reduces inefficiency, errors, and unnecessary expense by breaking down traditional engineering silos. At project onset using a mechatronic approach, electrical, mechanical, and software engineers address the actual product a customer wants to handle. They discuss the operations, or motions, required to form and handle the product, then make recommendations on how best to perform the operations. Precisely designed components—motors, drives, and gearboxes—can be viewed as standardized modular units fulfilling requirements for speed, torque, motion sequence, dynamics, and positioning accuracy. The engineers tap proven modular components and software, knowing precise specifications about what each can do.

After proffering design recommendations, the team collaborates to identify the implications of their recommendations on how the machine will ultimately perform. The simplicity of modular solutions more often than not results in better, stable product handling, and a safer, more efficient machine. Modules are selected and controls determined based on the features a customer needs. Code required to combine mechanical and electrical specifications is described according to machine functions—mechatronic modules, rather than programming language. The human machine interface (HMI) is developed using familiar terms, such as product dimensions and machine speed.

Through the collaborative machine building process, the entire team gains valuable insights into all three engineering disciplines. With each successive project, they are better equipped to assess feasibility relative to the other disciplines and, in many cases, take it to the next level by developing new machine control capabilities to expand customer offerings and support new business opportunities. Canned and tested modular components offer high reliability and combine engineering requirements, so the result is a smaller footprint. The process can yield innovative new methods to accomplish machine tasks. For example, a servo driven belt might replace a metal cam for a loading arm. Or, a frequency drive on a knee mechanism might replace hydraulics for high-speed, high-power applications. These machines are easier to support because fully integrated modules don’t require separate software.

Build a productive engineering team

Although a much-hyped industry buzzword, mechatronics is a relatively new concept. It can be challenging to find engineers with a solid education or experience in multiple engineering fields. A number of prominent engineering colleges offer courses in mechatronics, yet the moniker does not yet identify prospective candidates to fill real-world positions. The practice continues with hiring mechanical engineers, electrical engineers, and programmers as separate entities. Therefore, the best plan to secure qualified mechatronic engineers is to create in-house resources. A number of strategies can help create structure and develop in-house mechatronic resources.

Businesses that are under constant pressure to design and deliver machines don’t always make time for engineers to collaborate or innovate. The mechatronic approach requires top-down leadership to schedule some time to make R&D a priority. A simple, yet effective, entry ramp can be the rework of an old design taking a cross-discipline approach. Engineers must also stay abreast of current technologies. There is a near-constant stream of mechatronic innovation, some of which can vastly improve the machine design process and product. As an example, some vendors now offer software that combines panel layout with drive sizing and cam design. Motor-mounted drives can eliminate electrical cabinets, which have a direct impact on the mechanical design of a machine.

It pays to set specific goals when defining the scope of a mechatronic project. In some cases, goals may be communicated to customers as well. Achievement of benchmarks, such as a percentage in parts reduction, reliability, or energy efficiency, should be rewarded so the mechatronic team realizes the importance of continuous improvement via collaboration. Cross-training also plays a role in cultivating synergy. There must be a plan in place to provide detailed project information to each engineer on the team. A mechanical engineer who understands the potential of a control system will be more likely to simplify mechanical solutions. An electrical engineer who understands the “five simple machines” of physics will be more open to apply an open loop system or a smaller controller. A software engineer who understands “three sides of control” can synchronize the motion of a machine to guarantee the safe movement of product.

Leverage modular solutions for innovation

Modern machines are produced with faster lead times and designed to operate at considerably higher speeds than in the past. In the great race to meet production deadlines and budgets, innovation must never be an afterthought. Like mechatronics, innovation results from blending known elements to create something new. Consider the ubiquitous smartphone, for example, combining phone, camera, MP3, lighting, and touchscreen. By blending the tools based on CPU technology, smartphones become so much more. The same holds true for machine controls. A single touch panel can combine HMI, logic, and motion. Servos can be replaced with IP65 closed loop induction motor modules for cost savings and better inertia matching. Mechatronic engineers quickly recognize the short leap to tool-less changeover and data collection.

Industry standards have vastly improved machine programming consistency, so users have better and more flexible equipment and software choices. Open standards and tools have been instrumental in mitigating system integration issues, including inconsistencies in mode control and error reactions, commonly associated with proprietary programs. Application templates and ready-made standard software modules support machine builders in efficiently creating modular control software. Consider that about 80% or more of new machine tasks reflect some variation of past machine tasks. Design technologies exist to quickly and reliably handle many engineering requirements for standardized machine modules.

Use of modular code programming relies on a control system and modular hardware, but the impact in terms of reducing machine design resources is phenomenal. Software can be generated much more quickly using code developed for previous generations of machines in the form of ready-made technology modules, which can be modified to meet any new requirements. An application template provides the necessary basic structures while allowing users to create their own machine modules. Software modules created using application templates can then be put together like bricks with minimal effort, creating complete systems that are customizable and reusable. Preconfigured, reusable software modules for positioning, registration, cam profiling, multi-conveyor coordination, and other synchronized motion control tasks—including modules for feeding, unwinding, sealing, cross-sealing, and discharge applications—offer machine builders greater freedom and time to focus on developing and refining other value-added features of a new machine.

If not now, when?

When the goal is to build and deliver machines on time, efficiently, and within budget with the features a customer desires, mechatronics offers the most flexible and cost-effective path using modular components—with the balance of electrical and mechanical articulated in software. Increased demand for automation in broader applications has spurred development of smarter, more efficient drives, controls, and software tools. Automation products with embedded mechatronic functionality reduce engineering expenses while taking less real estate and offering more dynamic machine performance. The mechatronics design phase not only helps to ensure right-sized components, but also typically results in fewer parts, which translates to space and cost savings.

As more OEMs get on board with mechatronics, it becomes imperative that they manage the process and recognize mechatronic trends to stay ahead of the technology curve. By developing a portfolio of mechanical, electrical, and software modules, it becomes easier to quickly assemble “custom” machines to meet customer requests. Perhaps there’s an adjacent industry that could use machines similar to those your company builds. You know there’s potential for lucrative new sales. But do you know if the machine concept would work? There’s never been a better time to find out—and a mechatronic engineering team can make it happen.

– Tom Jensen is technology evangelist at Lenze Americas. Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske@cfemedia.com.

ONLINE

www.lenzeamericas.com

See related articles linked at the bottom for additional information.

Key concepts

  • Mechatronics is the convergence of power, electronics, and mechanical systems, including embedded software and hardware in engineering design.
  • Original equipment manufacturers manage design and use mechatronic techniques to stay ahead of the technology curve.
  • Developing a portfolio of mechanical, electrical, and software modules helps to quickly assemble custom machines to meet customer requests. 

Consider this