TME Inc.: University of Arkansas - Vol Walker Hall Historic Renovation and Addition

Retrofit and renovation of an educational facility.

08/14/2014


Exterior of Vol Walker Hall and Steven L. Anderson Design Center - University of Arkansas, Fayetteville. Courtesy: Mike Balch Photography Engineering firm: TME Inc.
2014 MEP Giants rank: 59
Project: University of Arkansas - Vol Walker Hall Historic Renovation and Addition
Address: Fayetteville, Ark., U.S.
Building type: Educational facility
Project type: other
Engineering services: Automation/controls, electrical/power, fire/life safety, HVAC/mechanical, lighting, energy/sustainability, and plumbing/piping
Project timeline: 8/2/2010 to 9/12/2013
MEP/FP budget: $8,721,000

Challenges

Renovating a historic building that once housed the University of Arkansas’s library from 1935 to 1968 was a challenge in and of itself. To compound it, the Fay Jones School of Architecture decided that the building should embody the sustainable features its curriculum promotes. Establishing a target of LEED Silver, the design team was ready to get to work. The existing building was listed on the National Register for Historic Buildings and is a “landmark” building for the University of Arkansas. Therefore, the design and construction were required to follow the University of Arkansas Preservation Master Plan as well as the Secretary of the Interior’s Standards for Rehabilitation for Historic Structures. This meant that the preservation of the main stair hall, east reading room (studio), and the dean’s office, which was originally designed by Fay Jones, was to be kept at the forefront of design. These areas were restored to the original construction. In addition to renovating the existing 56,635-sq-ft building, a new addition of 34,230 sq ft for the Steven L. Anderson Design Center was part of the scope. The dichotomy of renovation and new building design made for tricky circumstances when it came to having state-of-the-art, unified MEP/FP systems. Especially on the renovation side, it was like having to stuff an elephant in a clown car. The raised floor spaces were only 18-in. tall. The raised floors were erected on a support system with upright support members located every 24 in. All mechanical ductwork, fire sprinkler piping, electrical conduit, domestic water piping, vent piping, and so on, had to be coordinated and arranged such that it could be installed, supported, or restrained within the 18-in. vertical spaces and avoid conflicts with the hundreds of vertical floor supports located within each raised floor.

Auditorium at Steven L. Anderson Design Center - University of Arkansas, Fayetteville. Courtesy: Mike Balch PhotographySolutions

The challenge of renovating a 1935 building to meet LEED Silver Standards required complete replacement of all major systems within the existing facility. TME designed the MEP/FP systems with many energy-efficient features for both the new and existing facilities, including exhaust air energy recovery, high-efficacy lighting, variable volume chilled and heating water systems, an automatic temperature control system, energy management system, DDC and relative humidity controls, and a living, green roof. The energy model predicts that the building will perform 27.3% below the 90.1 (2007) baseline for energy efficiency. The project is expected to earn LEED Gold Certification, exceeding the design target of LEED Silver. To resolve the space issues caused by the raised floor in the existing facility, TME used Revit’s coordination and clash detection tools throughout the design process to ensure that the final set of plans was well coordinated for the entire team. This tool allowed team members to use the worksets of all MEP/FP system components to instantaneously find and resolve issues within the space. In some instances, the only way to coordinate the systems was to use duct sock in portions of the HVAC system, because it could conform to the tight and limited spaces in which it was installed and still allow other mechanical, electrical, and fire protection system components to be installed as well.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me