Tips and Tricks: 6 overlooked places to use industrial wireless

How Wi-Fi industrial wireless communications can save time, trouble, and money: Flexible work cells, mobile connections, and network enabling legacy devices are three overlooked areas to apply industrial wireless technologies. Three more are...

Mike Fahrion

05/14/2012


Technological advances like multiple-in-multiple-out (MIMO) transmitting and receiving are making Wi-Fi increasingly useful in industrial applications. Bandwidth and reliability have increased dramatically, and implementation costs have dropped. It’s worth rethinking some of the ways in which industrial data communications have been made in the past and considering where Wi-Fi can fit into the mix. Here are six overlooked locations to consider industrial wireless communications.

1. Flexible work cells

Industrial assembly was traditionally done by breaking down a process into individual steps and positioning machinery to maximize the efficiency and throughput of each machine. But that model lacked the flexibility needed for the production of small and customized lot sizes. The solution is the work cell, where the machinery and devices required for a specific project can be temporarily grouped together, and released for other uses as dictated by circumstances. But that means recabling the work cells every time there’s a change. Wi-Fi makes it easier, and cheaper, to set up and rearrange work cells.

2. Mobile connections

Mobile connections: In a shipping and receiving application, a Wi-Fi access point enables mobile equipment to stay connected to the network, even as it moves around a plant.

Cable connections don’t allow for much mobility. In applications like shipping and receiving, where the value of mobile machinery like forklifts is greatly enhanced if those devices have network connections, an industrial-grade Wi-Fi wireless access point (such as the APXG-Q5420 from B&B Electronics) can keep mobile equipment connected to the network even as it moves around a plant. A truck could connect to a forklift to download or upload delivery manifests and shipment details. Inventory systems, printers, scales, and other tools can communicate directly with a vehicle to expedite workflow. Wi-Fi clients like laptops, tablets, or smartphones can connect directly to the vehicle. Even vehicle maintenance is simplified, as onboard diagnostics and telematics can be monitored directly or from a remote location.

3. Network-enabling legacy devices

The enormous installed base of devices using serial communications isn’t going anywhere any time soon. But as newer protocols like Ethernet and Wi-Fi have appeared, it is becoming harder to find laptops or computers equipped with serial ports.

Network-enabling legacy devices: APXG is B&B’s Wi-Fi wireless access point (AP) (which also serves as a router or network bridge). The B&B APMG is the embeddable version of the Wi-Fi AP.

One solution is to equip serial devices with wireless Ethernet serial servers. Wireless serial server technology can turn a serial device into one more node on the network and give it communications capabilities that it was never designed to possess. A serial device could also be equipped with an embedded Wi-Fi access point module (like the APMG-Q551 from B&B Electronics), which creates a self-sustaining wireless hotspot much like the one at the corner coffee shop. Handheld Wi-Fi clients can then connect to it using Android, Apple iOS, or Microsoft Windows operating systems.

4. Cable vulnerability

Although network cables are commonly run under floors, or through walls or drop ceilings, some portion of the cable must eventually be exposed as it makes the final run to an attached device. That’s not a big issue in an office environment, but in industrial applications that final run leaves a cable vulnerable to serious damage. Cables may be crushed by moving machinery, stepped on, pulled, bent, or soaked in damaging fluids like solvents. And when cables fail, installing new cable is often cheaper and easier than tracking down the fault point in the existing installation. If this happens often enough it will ultimately create a confusing rat’s nest of old and new wiring.

The problem is magnified in temporary installations at remote locations. Imagine setting up a large generator system for a remote construction site, or to provide temporary power after a natural disaster. You’d need to tie together everything from supervisory control and data acquisition (SCADA) to Modbus network communications, and you’d be working in a slightly disorganized environment full of moving vehicles and workers. Murphy’s Law tells us what would happen to any exposed cable. Trenching your cable would help, but it would add time and expense to the project. And the final run would still be highly vulnerable. It would be easier to do the job with Wi-Fi.

5. Hard-to-wire locations

Hard-to-wire locations: An off-the-shelf Wi-Fi bridge creates a reliable network connection across a river to a remote pump station, where running cable would be prohibitively expensive.

Sometimes you just can’t wire a widget. The expenses involved in running cable over a river or highway, for example, can be prohibitive. Even an indoor installation can be problematic, depending on where a device needs to be placed.

And moving data any significant distance over cable will call for expensive fiber optic cables, receivers, and transceivers. Fiber optic cable provides for enormous bandwidth and, as demonstrated by the telcos, it will carry data across entire continents. But how many applications would actually require that much range or bandwidth? For far less money you can install off-the-shelf Wi-Fi bridges (such as the Ghostbridge from B&B Electronics), which can create connections with speeds of up to 150 Mbps at distances of up to 15 km, depending upon local conditions.

6. Hazardous locations

In 1989 a solar flare created a magnetic storm that knocked out the power grid for all of Quebec, Canada, by inducing unexpected current on the power lines. Industrial motors and other high-power devices create magnetic fields that will affect nearby copper cabling in much the same way, though on a smaller scale. With luck, the only result will be data transmission errors and blue screens. But more serious events will damage expensive equipment.

And the greater the distance between connected devices, the more likely it becomes that communicating devices will be getting their power from different building ground references. When they do, copper cable can create a ground loop path. Again, you’ll be able to count yourself lucky if the only result is a blue screen.

These problems can’t be addressed with ordinary surge suppression, which only tries to limit spikes between the signal and ground line. (When the ground line rises, as it does in ground loop situations, surge suppression won’t stop it.) You could install isolators, which allow the lines to float while keeping the local side at the proper ground and signal level. And you could invest in fiber optics, which are natively immune to electromagnetic interference (EMI), spikes surges, and ground loops.

But if you’d prefer to save yourself some money and trouble, you could just use Wi-Fi.

- Mike Fahrion is data communications expert and the director of product management for B&B Electronics; Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer. He can be reached at mhoske(at)cfemedia.com.

www.bb-elec.com

About the author

Mike Fahrion, the director of product management at B&B Electronics, is an expert in data communications with 20 years of design and application experience. He oversees development of the company’s rugged M2M connectivity solutions for wireless and wired networks based on serial, Ethernet, wireless, and USB communication technologies. Fahrion is a speaker and author who writes a self-described politically incorrect newsletter, “eConnections,” with more than 50,000 monthly subscribers.

 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.