Tiny linear servomotor is piezo application replacement

Nippon Pulse America's Linear Shaft Motor, which is 4 mm in diameter, is reportedly designed to be a replacement in piezo-type applications.

08/23/2011


Nippon Pulse America introduced its smallest linear servomotor, the 4 mm Linear Shaft Motor. The 4mm shaft diameter, a small forcer size (10 mm x 10 mm), a total weight of 9 grams, and strokes as long as 40 mm make the 4 mm Linear Shaft Motor a suitable replacement in piezo-type applications. 

The 4 mm Linear Shaft Motor is reportedly quiet due to the absence of friction since the only mechanical contact section is the linear guide. The coreless construction of the Linear Shaft Motor totally eliminates cogging.

The Linear Shaft Motor's high motor stiffness allows it to be used in high precision positioning applications where a resolution of 0.09 nanometers is achievable. With the Linear Shaft Motor, you will find that you have virtually no fluctuation in speed.

Durable construction makes it possible to operate the Linear Shaft Motor in harsh conditions, including a vacuum situation and underwater.

Compared to other linear motors on the market, the Linear Shaft Motor is compact and lightweight. Due to its design, the Linear Shaft Motor has no backlash.

Specifications for S040D Linear Shaft Motor:

  • Continuous stall thrust - 0.5 N
  • Continuous stall current - 0.4 A
  • Peak thrust 2 N
  • Peak current - 1.8 A
  • Shaft diameter (D) 4 mm (0.16 in.)
  • Slider length (A) 25 mm (0.9 in.)
  • Slider width (B) 10 mm (0.39in.)
  • Mounting pitch (P x P1) 21.5 x 4 mm
  • Mounting screw (M x l) 4-M2
  • Gap 0.5mm (0.02 in.)
  • Slider weight 0.01 kg/F
  • Available stroke 20, 30 & 40 mm
  • Magnetic pitch (N-S) 9 mm (0.354 in.) (N-S)

www.nipponpulse.com 

Nippon Pulse America

- Edited by Chris Vavra, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me