Tie best of breed CMMS with your ERP and reap the business benefits

Most corporate departments think of maintenance when they need the thermostat adjusted in the conference room. But maintenance management and CMMS are an integral part of ERP, which runs 80% of Fortune 1000 companies

07/02/2013


Most corporate departments think of maintenance when they need the thermostat adjusted in the conference room. But maintenance management and CMMS are an integral part of ERP, which runs 80% of Fortune 1000 companies. CMMS is an essential tool for managing operations and maintaining assets across the enterprise. CMMS drives quality production, ensures regulatory compliance and controls operating costs.

So how do you run a smooth maintenance operation, keep assets humming and integrate with the company’s ERP system? Before you start coding a new ERP interface, weigh the issues. Is the CMMS integration a desire for the maintenance department or a directive from the COO? How can CMMS and ERP integration reduce operating costs and contribute to business performance?

Once you answer the big picture questions and decide to move forward, consider these guidelines from someone who’s been there, done that…

First, make sure you think through your points of integration. Synchronize part quantities vs. share a completed purchase order (PO)—this is an important debate. Some ERP systems make it difficult to share a whole purchase order, so perhaps synchronizing spare parts in your CMMS with the ERP POs is a better approach.

Do you have internal expertise, or at least affordable consulting on the ERP side? These costs can add up. It is likely your ERP system will need configuration support to make this interface work.

Don’t rush into the integration. Get to know your CMMS first, for a few weeks or even several months before finalizing your integration plans. Product experience will influence interface approach/design, and is a safer, less expensive endeavor than building the interface in advance.

Assess your CMMS needs. Understand that although a CMMS vendor may have interface capabilities off-the-shelf, the interface will always need to be configured for the organization’s environment—either on the CMMS or ERP side, or both. Configuration depends on the IT environment, ERP system and version, desired integration points, in-house ERP expertise, etc. Automated interfaces should be considered semi-configured (in some cases total custom) projects.

In theory, a quality CMMS vendor should have the technological capabilities to allow any information to be passed to and from an ERP system. Most common interfaces I have developed are related to spare parts. Others include sharing “finished” purchase orders/requisitions, asset information (status, location, costs, etc.), and employee data, typically labor rates or department information.

Most importantly, have the discussion with your maintenance team. Define the business goals. Identify the integration points. Your CMMS vendor won’t be able to discuss development costs unless you have thought through the project. Do your homework upfront so CMMS and ERP can make the connection a lasting one.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me