The rocky relationship between safety and security

This webcast examines best practices for avoiding common cause failure and preventing cyber security attacks in an age of open systems and system integration.

11/06/2012


The Rocky Relationship Between Safety And Security:

Best Practices For Avoiding Common Cause Failure And Preventing Cyber Security Attacks In Safety Systems

Now available for viewing on-demand.
Original broadcast was Nov. 6, 2012; runtime with question and answer session is one hour.

Click here to register.

In this day of open systems and integrated industrial networks, does your safety system still maintain an acceptable level of separation? Can it protect your process from cyber attacks? International safety standards (i.e. IEC 61508) press the need for independence among the multiple protection layers on an industrial site "…the EUC control system shall be independent from the E/E/PE safety-related systems and other risk reduction measures…" But does this still happen in real life? Digital safety systems (electronic/programmable electronic systems) typically have communication ports with support for open protocols, such as Modbus RTU, in order to provide diagnostics and other information relevant for running the process.

Users have connected (interfaced) safety systems to BPCS since mid 1980s and aimed to develop tighter connectivity at least since 1995, but these efforts were based on proprietary protocols until the adoption of open network protocols and Windows on industrial control systems increased the connectivity to business systems and at the same (at least in theory) exposed them to the same issues (virus, cyber attacks, etc).

This Webcast will discuss the methods used to ensure that the integration between the safety system and the BPCS DO NOT compromise Functional Independence and the best practices to secure an industrial system and in particular safety systems in this integrated environment.

Presenters:

  • Luis Durán, Product Marketing Manager Safety System, Control Technologies/Process Automation, ABB
  • Greg Hale, Editor/Founder, Industrial Safety and Security Source and Event Moderator

Sponsored by: ABB

https://www.surveymonkey.com/s/F9KCXLB



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me