The Economics of Intelligence

02/01/2006


Discussion of intelligent buildings is great, but without bottom-line numbers, most clients—and without question, almost all commercial developers—just don't want to hear it.

To arm designers with ammunition to launch an effective sortie, intelligent systems consultant Paul Ehrlich, P.E., in his Building Intelligence Tour seminar at the ASHRAE Winter meeting last week in Chicago, laid out some numbers engineers can hopefully take to the bank.

In his example, Ehrlich ran through a scenario of an owner-operated building and a developer-operated building. To put in the various systems to make a building intelligent, Ehrlich estimated it adds about $3 to $5 per sq. ft. for new construction and $4 to $6 for retrofits. For the purpose of this scenario, he settled on $4. For a 150,000-sq.-ft. building, the investment for intelligence is $600,000. As far as energy savings, intelligent systems should yield a payback of about a $1 per sq. ft. with a simple payback of four years and an ROI of 95% over five years.

As far as fuzzy tangibles, such as greater employee productivity, Ehrlich estimated an intelligent building should raise productivity by 1%—or $1.40 per sq. ft. For the sample building, that's an improvement of $210,000, with a simple payback of 1.7 years and an ROI of 227% over five years. Not bad, said Ehrlich, but nothing to get excited about.

Now comes the commercial project. First, Ehrlich said, most commercial developers don't want to hear anything about energy savings, so a very different approach is recommended, one that stresses how they can make money. Given the same $600,000 investment, the building should see an energy savings of about $120,000 ($0.80 per sq. ft.), but the big opportunities involve increasing rents and the number of tenants occupying the building. For both of these categories, Ehrlich said developers should be able to raise fees for both by 4%, given Building Owners and Managers Assn. (BOMA) research stating that tenants would pay more to work in an intelligent building. That's a combined rent/occupancy improvement of $300,000. Simple payback calculates to 1.4 years with an ROI of 265% over five years.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me