SEARCH Archives
Loading
Sponsored by:

Test Instruments, Meters, Data Loggers

Finalists in Test instruments, meters, data loggers for Consulting-Specifying Engineer's 2012 Product of the Year competition

04/16/2012


Power quality analyzers

430 Series IIThe Fluke 430 Series II three-phase power quality and energy analyzers are handheld tools that measure electrical power consumption, quantify wasted energy, and improve the performance and lifespan of electromechanical equipment. Three measurement functions are combined with hardware, software, and firmware improvements. The Unified Power function provides the ability to calculate the monetary cost of the wasted energy and to automatically quantify the energy wasted by harmonics and unbalance. The Inverter Efficiency function simultaneously measures the input and output power inverters. The 435 model includes PowerWave, a “fast capture” system that displays waveforms, half-cycle RMS voltage, and current values to measure interaction during switching operations. These analyzers have up to 32 GB memory, a swappable SD memory card, and USB connectivity.


Smart meters

Series 3000Leviton’s Series 3000 line of UL-listed smart meters measure power use in a building with enhanced measurement functionality, greater communications capabilities, and indicators to ensure proper installation and accurate data collection. Designed for commercial, institutional, industrial, and government applications, these meters monitor power consumption for individual tenants, departments, and pieces of equipment, or other loads, to account for their actual energy usage. They measure kWh, demand, instantaneous power, V, A, W, VAR, and VA per phase. These meters are equipped with an isolated pulse output channel and an RS-485 two-way serial port and open architecture platform for integration with AMR/BAS/BMS/EMS systems.


Thermal imagers

P3 Series thermal imagersFluke added four additional products to the P3 Series thermal imagers: the Ti27 and Ti29 models measure temperature from -20  to 600 C with a high temperature color alarm for industrial applications, and the TiR27 and TiR29 models measure temperature from -20 to 150 C with a low temperature or dewpoint color alarm for building inspection and maintenance applications. These thermal imagers feature interchangeable lenses, 76,800 total pixel image count for the Ti32/TiR32 models, thermal and spatial resolution with Fluke IR-Fusion that simultaneously displays visible light and infrared images, and Fluke SmartView professional IR software for viewing, annotating, editing, and analyzing.

 


<- Back to: Product Categories

 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.