Ten Tips for Quality Compressed Air

These suggestions are some of the most effective actions that a design professional can take to design a quality pneumatic-air system-and to ensure that it is maintained correctly: Maintain a low dew point, but not lower than what is needed. Filter the air of harmful particulates. Avoid bypasses to filters and dryers. Get as much of the oil out as possible.

03/01/2001


These suggestions are some of the most effective actions that a design professional can take to design a quality pneumatic-air system-and to ensure that it is maintained correctly:

  • Maintain a low dew point, but not lower than what is needed.

 

  • Filter the air of harmful particulates.

 

  • Avoid bypasses to filters and dryers.

 

  • Get as much of the oil out as possible.

 

  • Consider going to an oil-free system.

 

  • Convert to heat-of-compression dryers.

 

  • Consider a desiccant dryer for only part of the system, if only a small part is exposed to the outdoors.

 

  • Avoid installing a refrigerated dryer upstream of a heatless desiccant dryer.

 

  • Find and fix leaks.

 

  • Consider variable-speed-drive (VSD) compressors.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me