Tees for joining black iron pipe

Reducing tee configurations for the MegaPress and MegaPressG system for joining schedule 5 to schedule 40 black iron pipe in sizes 1/2 to 2 in.

07/01/2016


Reducing tee configurations for the MegaPress and MegaPressG system for joining schedule 5 to schedule 40 black iron pipe in sizes 1/2 to 2 in. Courtesy: ViegaViega's reducing tee configurations for the MegaPress and MegaPressG system for joining schedule 5 to schedule 40 black iron pipe in sizes 1/2 to 2 in. The MegaPress system uses cold press connections for pipe installation and is designed for hydronic heat, chilled water, compressed air, fire sprinkler systems, low pressure steam, and vacuum lines. MegaPressG fittings are designed for use in fuel oil and natural gas applications. MegaPress fittings include elbows, couplings, reducers, tees, reducing tees, threaded adapters, caps, flanges, and unions. The fittings use a stainless steel grip ring with an EPDM sealing element along with a stainless steel separator ring.

Viega

www.viega.us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me