SEARCH Archives
Loading
Sponsored by:

Synchronous belt drive system adds 5% efficiency over V-belts

Baldor’s new Dodge synchronous belt drive system uses Dodge HTR and HTRC Tracker belts; the system is energy efficient, maintenance free.

12/30/2010


Baldor Electric Company, manufacturer of energy saving industrial electric motors, mechanical power transmission products, drives and generators, introduces a new synchronous belt drive system uses Dodge HTR and HTRC Tracker belts. The belts have a Reinforced Parabolic Profile (RPP) tooth design allowing the belt teeth to sit deeper in the sprocket compared to standard belts. Combining these belts with Dodge Taper-Lock sprockets yields the most power dense rubber synchronous drive system in industry.

The unique angle of the RPP Tracker belts allows synchronous transmission of power, eliminating slippage and speed variation on high torque applications. TapeLock sprockets are machined to the highest quality standards, ensuring a match between the sprocket and belt. By maximizing performance of the belt and the sprocket, the new synchronous drive system delivers 5% more energy efficiency over properly maintained V-belt systems.

The neoprene rubber belts are manufactured with an advanced fiberglass cord that provides superior tension stability and prevents moisture from being absorbed. With no belt shrinkage or stretch, this belt will not have to be re-tensioned making it virtually maintenance free. Belt construction also helps reduce the belt installation tension, increasing the life of the other mechanical components.

When compared with a QD style product, the Dodge Taper-Lock sprocket design requires less shaft length, offers more bore sizes per bushing size, and delivers more torque. The Dodge sprocket system also minimizes overhung load by positioning the belt’s center line closer to the motor, reducer and bearings. Plus, a new anti-corrosion coating improves rust prevention.

The Dodge line of synchronous sprockets offers more tooth configurations than other synchronous products. Now, combined with the new HTR and HTRC Tracker belts, this belt drive system offers the greatest opportunity for speed and center distance matching, while achieving power ratings up to 1,200 hp.

Designed to meet customer needs in a wide variety of applications, the HTR offering is an average strength belt, while the HTRC is a higher strength belt ideal for high horsepower and high torque applications.

With superior power dense performance that’s easy to install, easy to maintain, and energy efficient, the new Dodge HTR and HTRC Tracker synchronous belt drive system offers the best total cost of ownership solution for the marketplace, the company said.

Dodge Drive Components (PDF)

www.baldor.com Baldor



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.