Switchgear Bolsters Transfer-Switch Producer

Officials at a Chicago-based manufacturer of automatic transfer switches decided to put their money where their mouth is and install their own paralleling switchgear in their backup power system. The system, which controls the operation of two engine-generators—a 225-kW unit and a 175-kW unit—provides the backup power for the entire plant.

06/01/2001


Officials at a Chicago-based manufacturer of automatic transfer switches decided to put their money where their mouth is and install their own paralleling switchgear in their backup power system. The system, which controls the operation of two engine-generators—a 225-kW unit and a 175-kW unit—provides the backup power for the entire plant. Upon loss of incoming utility power, the system automatically starts the two engine-generators, synchronizes the output and then feeds the plant loads through automatic transfer switches. The system is also used as part of the local electric utility's interruptible-rate program, which helps the utility manage its peak loads when energy requirements are at a premium.

In addition to alarming, reporting and trend-analysis capabilities, the control system provides wireless access from a personal data assistant and remote monitoring via Internet or corporate intranet. Other key features include:

  • Engine-generator start, stop, crank and cool-down control.

  • Engine-generator emergency operation during a utility power failure.

  • Power monitoring and protection.

  • Web-enabled graphical user interface for eased configuration.

  • Multiple section switchgear with insulated-case circuit breakers.

  • Eight logical relay functions and 12 user-programmable relays.

  • Alarm/event logging for trend analysis and management reporting.

  • Interface with electronic as well as generic hardwired engine generators.

The new system replaces a 20-year old paralleling switchgear, and management expects a payback through operational efficiencies and energy savings.

For information about Entellisys or Series ZTS from GE Zenith, circle 101 on the Reader Service Card.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me