Sustainable Water System Design

When undertaking projects, especially in a desert or tropical climates, it is important to consider sustainable technologies for water-system design. And anywhere a project is located, energy efficiency should be a key sustainability concern.Domestic hot-water storage is a large energy consumer.

02/01/2001


When undertaking projects, especially in a desert or tropical climates, it is important to consider sustainable technologies for water-system design. And anywhere a project is located, energy efficiency should be a key sustainability concern.

Domestic hot-water storage is a large energy consumer. The formerly common practice of lowering the storage temperature has proven to cause other problems, so one can be left with the need to store water at 140 degrees.

High-efficiency water heaters with improved insulation systems should be considered. Point-of-use electric heaters can reduce the quantity of stored water, simplify thermostatic mixing-valve piping and lower recirculation losses. Similarly, low-consumption fixtures can reduce the demand for hot water, and self-regulating heat-tracing reduces recirculation losses. While many of these solutions reduce energy at the meter, it is at the cost of using more global energy.

A related system is wastewater-heat recovery . This commercially available system uses a falling-film heat exchanger to extract energy from the waste stream and transfer it to incoming cold water. For buildings with high hot water usage, this can save a lot of energy. Because the drainage piping is arranged to recover the warmest water-which is close to the incoming cold water-this improves performance.

On-site biological waste treatment is also making inroads on highly sustainable projects. Turnkey solutions treat the waste stream in such a way as to have no net increase in required off-site waste treatment.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me