Superconductor Fault Current Limiter Demonstrated in China Power Grid

01/26/2006


American Superconductor Corporation, Westborough, Mass., and China's Institute of Electrical Engineering (IEE) announced recently that IEE has successfully demonstrated a superconductor-based fault current limiter—essentially a high voltage surge protector—for the first time in a power grid in China.The device was fabricated by IEE in collaboration with the Technical Institute of Physics and Chemistry and Hunan Electric Power Company utilizing "smart" high temperature superconductor (HTS) wire manufactured by AMSC.

Since August 2005, IEE's fault current limiter device has successfully suppressed large spikes of current in the grid that were over five times the normal levels.Superconductor wires are considered smart because they possess unique physical properties that allow them to react instantaneously to current surges, passing electricity along at normal levels while also being able to recognize and then suppress large surges of electrical current.Suppressing spikes of electrical current is important because it prevents damage to expensive electrical equipment in power grids. Fault current limiters cannot be made from conventional materials such as copper wire.

According to Dr. Liye Xiao, Deputy Director of the IEE and Director of the Applied Superconductivity Laboratory at the ChineseAcademy of Science, this project is an important step in demonstrating the value of these devices in greatly improving the reliability and stability of power grids in China."Demand for electric power in China continues to grow dramatically year-over-year," said Dr. Xiao."We need to utilize innovative devices, such as fault current limiters and superconductor transformers and power cables, to guarantee the reliability and stability of our power grids because electricity is the lifeblood of our rapidly growing economy."

"This demonstration project is a critical step on the path to commercial sales of superconductor fault current limiters in China - a market that we believe will be very large," said Greg Yurek, chief executive of AMSC.The U.S. Department of Energy estimates that the market for superconductor fault current limiters in the U.S. alone will be several billion dollars over the next 15 years."We expect the market in China to be even larger because grids there are already approaching the limits of circuit breakers in their rapidly expanding cities," said Yurek.

For more information, click here .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me