State-of-the-Art BAS in the UAE

In regions of the world where tourism is growing, often what distinguishes competing hotels and convention centers is the technology made available to guests, be they tourists or business people. Such is the case with the Dubai's Emirates Towers in the United Arab Emirates. Among the tallest buildings in the Middle East—at 1,165 ft.

11/01/2002


In regions of the world where tourism is growing, often what distinguishes competing hotels and convention centers is the technology made available to guests, be they tourists or business people. Such is the case with the Dubai's Emirates Towers in the United Arab Emirates.

Among the tallest buildings in the Middle East—at 1,165 ft.—the towers' building automation system incorporates four graphic workstations that manage and integrate 20 building systems, including HVAC, fire alarms, CCTV, lighting, hotel and property management systems, an IT network based on asynchronous transfer mode (ATM), and Gigabit Ethernet technology.

The backbone is a high-tech network infrastructure capable of supporting different multimedia, voice, video and data services, which is ideal for the tower's office and conference facilities.

"The vision for Emirates Towers was to create a state-of-the-art technological infrastructure, which could be scalable to future information as building management technology developments," says Ivan Brinkley, corporate technical director for Jumeirah International, the facility's owner.

The taller of the spires houses office space, and the second is a five-star hotel with 500 rooms. The towers are connected via a five-story structure incorporating 96,875 sq. ft. of space, and 40 stores and restaurants.

To ensure the most flexibility, the integrated system was designed with open protocols and standards. System architecture is also capable of integrating with different voltage systems found among the chillers, elevators and fire-alarm systems.

Because Dubai is situated in the middle of the desert, summer temperatures can reach 120°F, so temperature control is critical. Consequently, office areas and guest rooms are equipped with LonMark DDC controllers connected to the facility's LAN.

Additional systems tied into the BAS include power monitoring, paging and computerized maintenance management.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me