Solid-state cylinder switch

The SMT-8M-A solid-state cylinder switch by Festo features a supplemental on-board LED for proper field commissioning and is designed for T-slot applications on pneumatic drives.

02/22/2013


The SMT-8M-A solid-state cylinder switch by Festo features a supplemental on-board LED for proper field commissioning and is designed for T-slot applications on pneumatic drives. Courtesy: FestoThe SMT-8M-A solid-state cylinder switch by Festo is designed for for T-slot applications on pneumatic drives. 

The SMT-8M-A switch is loaded with new features yet the footprint of the switch has been reduced by almost 20 percent, making it one of the most compact solid-state cylinder switches in the market. The SMT-8M-A switch includes both NO/NC and PNP/NPN options in the same housing, giving flexibility to the customer in terms of switching choices and eliminating the need to stock multiple spare parts. The power supply range to 5 V dc on the lower end provides the flexibility to link the output signal directly to a TTL circuit.

The cable quality is superior and makes the sensor completely reliable in drag-chain applications and even on robot arms. It has dust-proof and explosion-proof features that add to application reliability in harsh environments. Its protection rating of IP69K makes the cylinder switch ideal for high temperature and high pressure wash-down applications. In addition, the output signal is guaranteed to stay ON for at least 4 ms in high-speed applications where switch-ON signals could be missed.

Features such as an additional cable clip and supplemental onboard LED aid in easy installation and commissioning in the field as does the sensor’s configurability. The sensor also ships with label-holders at each cable extremity, making it easier to document the sensor in the field.

Festo

www.festo.com/us 

- Edited by Control Engineering. See motors and drives products.

See other sensor products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me