Smart Grid-Ready Telecontroller

Ethernet 2.0 ECO Telecontroller by Wago converts signals via connected IO into IEC-compliant data and maximizes space within compact substation control cabinets.

01/23/2013


The Ethernet 2.0 ECO Telecontroller by Wago converts signals via connected IO into IEC-compliant data and maximizes space within compact substation control cabinets. Courtesy: WagoWago expanded their Smart Grid-Ready I/O portfolio with the DIN-rail mount Ethernet 2.0 ECO Telecontroller. ECO Telecontroller supports Smart Grid integration of small, localized renewable energy producers. These producers accommodate a limited amount of I/O. Since utility incorporation relies on collecting precise network states, the ECO Telecontroller facilitates this by converting signals via connected I/O into IEC-compliant data.

Packing an integrated Ethernet switch and dual Ethernet ports, 750-880/0025-0002 ECO TeleController maximizes space within compact substation control cabinets. ECO TeleController's SD Card Memory Expansion slot supplements 1 Mbyte of data memory with up to 32 Gbytes of additional memory. It also allows transfer of device parameters or files, e.g., boot files, from one controller to another.

Applications include power reduction of renewable energy units, or the polling of thermal power stations to virtual power stations. Typically, small energy producers require just four modules and an End Module. Example: A power supply, two four-channel DI, one 4-channel AO and one 2-channel AI, ending the K-bus with a 750-500 End Module.

Wago Corporation

www.wago.us 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me