Small motors: Nidec Copal sub-miniature step motors in 4, 5, 6, 10 mm sizes

Tiny step motors: Nidec Copal developed a new family of sub-miniature step motors; the smallest is a the LPD4 with a 0.157-in. (4 mm) outside diameter by 0.32-in (8.5 mm) axial length, rated at 3 V dc input.

11/05/2009


Enlarged to show detail...

Nidec Copal 4 mm, 5 mm sub-miniature step motors

Nidec Copal 4 mm, 5 mm sub-miniature step motors

Torrance, CA - Nidec Copal has developed a new family of sub-miniature step motors with the LPD4 (4 mm) and LPD5 (5 mm) representing the smaller of the four member step motor family. The Nidec Copal model LPD4 is a 0.157-in. (4 mm) OD by 0.32-in. (8.15 mm) axial length step motor rated at 3 Volts dc input. The 22.5 degree per step motor develops a holding torque of 0.023 ounce-inches. Maximum pull in speed is 1600 pulses-per-second (pps). Maximum pull out speed is 3000 pulses-per-second. The larger LPD5 model is a 0.197-in. (5 mm) OD by 0.165-in. (4.2 mm) axial length furnishing 0.01 ounce-inches of pull in torque over a wide speed range up to 2000 pps. Input voltage is 4.3 vdc and the LPD5 step angle is 18 degrees per step. Typical applications include miniature medical pumps, fiber optic actuators, camera focus drives, etc. For further information about the LPD4, LPD5, and the two larger LPD6 and LPD10 models, please contact Nidec Copal (USA) Corp. www.nidec-copal-usa.com.

Also read from Control Engineering :

- Small motors market surging in Americas ; and

- Rise of the PM (permanent magnet) machines .

- Edited by Mark T. Hoske, editor in chief, Control Engineering , www.controleng.com





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.