Skyhouse Atlanta Midtown

New construction; Skyhouse Atlanta Midtown; Jordan & Skala Engineers

08/15/2013


This photo shows the exterior view of the 23-story tower. Courtesy: Jordan + Skala EngineersEngineering firm: Jordan & Skala Engineers
2013 MEP Giants rank:
53
Project:
Skyhouse Atlanta Midtown
Address:
Atlanta, Ga., United States
Building type:
High-rise residential
Project type:
New construction
Engineering services:
Electrical/Power, HVAC, Lighting
Project timeline:
April 2011 to January 2013
Engineering services budget:
$15 million
MEP budget: $15 million

Challenges

The Skyhouse Atlanta Midtown project had to earn the This interior view of a living unit shows night skyline views. Courtesy: Jordan + Skala Engineersapproval of the Multi-Family High-Rise (MFHR) program, indicating that the building uses less water and is at least 15% more energy efficient than multi-family high-rise buildings built to the base energy code. One primary challenge of the project was being able to give the owner a building that meets Energy Star criteria while incorporating a high percentage of glass and pressurized corridors. Overcoming the HVAC load demands from these design decisions, while remaining cost effective and within the boundaries of Energy Star requirements, required thoughtful engineering. Additional engineering concerns included installing a backup generator inside the facility. Due to the urban setting and large building A view of the amenity area is shown. Courtesy: Jordan + Skala Engineersfootprint relative to the property line, the generator was installed in the facility and had to comply with all codes related to exhaust and clearance concerns. From initiation to occupancy, this 23-story project was designed and constructed in just 12 months.

Solutions

Located at 1084 West Peachtree Street in the center of trendy Midtown, and smartly positioned between the iconic Atlanta development landmarks of Atlantic Station, Tech Square, the Arts Center, and Colony Square, the new, 23-story Skyhouse Atlanta apartment building offers 320 units, luxury amenities, a rooftop pool, a parking deck, and retail space on the ground floor. The building showcases sustainable details that reduce utility costs for the property manager and individual tenants, as well as provide greater creature comfort. Jordan & Skala designed the mechanical, electrical, and plumbing systems, which feature the following energy-efficient components:

  • High-performance exterior windows and doors with thermally broken frames 
  • High-performance building envelope using increased continuous wall and roof insulation
  • High-efficiency heat pump HVAC systems
  • Energy Star appliances
  • Low-flow water-sense plumbing fixtures
  • Premium efficiency motors on domestic water pumps
  • High-efficiency fluorescent/LED lighting throughout the building
  • Occupancy lighting sensors in all public spaces
  • Continuous ventilation in all living units, thus improving indoor air quality.

To ensure designs and systems perform as specified, many of the building's systems, equipment, and exterior envelope underwent a detailed testing and verification protocol in accordance with Energy Star criteria to ensure the client's objectives were met. With units ranging in size from 557-sq-ft studios to 1418-sq-ft, three-bedroom apartments, the building offers a rooftop pool, an amenity deck, a spacious clubroom, a state-of-the-art fitness center, and breathtaking views. Jordan & Skala was pleased to beneficially contribute to the high-rise homes of hundreds of future Midtown residents. The overwhelming success of this project resulted in Jordan & Skala, and the entire design and construction team, being awarded additional Skyhouse projects in Austin, Houston, and Dallas, Texas; Tampa and Orlando, Fla.; Raleigh and Charlotte, N.C.; and a second version of this project in Atlanta, Ga.

View a short presentation from Jordan & Skala on this project.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me