Shaft grounding ring

This Shaft Grounding Ring Protects Medium-Voltage Motors and Generators from Bearing Failure.

09/29/2010


The AEGIS iPRO Bearing Protection Ring from Electro Static Technology extends the life of medium-voltage motors and improves the reliability of systems in which they are used by safely channeling harmful electrical currents away from bearings to ground.  Specially designed for high-current applications, the AEGIS iPRO protects generators, turbines, and medium-voltage motors against electrical bearing damage.

The AEGIS iPRO prevents damage that could otherwise lead to generator or motor failure, unplanned downtime, costly repairs, and lost revenues.  It is available in a range of sizes to accommodate generator/motor shafts up to 30 in. in diameter.  To facilitate field retrofits, the iPRO split-ring comes in mating halves that simplify installation around the shafts of coupled equipment.  Common sizes (for motor shafts between 2.5 and 12 in. in diameter) are typically shipped within five days.

If not diverted, shaft voltages induced by variable frequency drives (VFDs) discharge through the bearings of motors, generators, and coupled equipment.  Embedded securely in the AEGIS FiberLock channel along the inner circumference of the iPRO, six rows of conductive microfibers completely surround the motor shaft, providing millions of discharge points for harmful shaft currents and creating the path of least resistance that effectively diverts these currents away from bearings to ground.

The AEGIS iPRO is ideal for medium-voltage motors that drive pumps, compressors, mixers, shredders, conveyors, and other machinery used in mining, food processing, wastewater treatment, petrochemical refining, and many other applications.  It is also ideal for protecting the bearings of generators in both utility and on-site power generation systems.

Compatible with current-monitoring equipment, the AEGIS iPRO is engineered to safely divert high-current and high-frequency dv/dt shaft currents and works in the presence of oil, dirt, grease, or other contaminants.  As part of a preventive maintenance program, it can be installed whenever bearings are replaced.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.