Servo terminal IO provides power, feedback signals

Beckhoff Automation's EL7201-0010 servo terminal supports One Cable Technology (OCT) and has an EtherCAT I/O system integrate a complete servo amplifier for motors.

05/07/2014


Beckhoff Automation's EL7201-0010 servo terminal supports One Cable Technology (OCT) and has an EtherCAT I/O system integrate a complete servo amplifier for motors. Courtesy: Beckhoff AutomationBeckhoff Automation's EL7201-0010 servo terminal supports One Cable Technology (OCT), which combines power and feedback signals into one streamlined cable. The EL7201 series servo terminals from the Beckhoff EtherCAT I/O system integrate a complete servo amplifier for motors up to 200 W in a compact High Density (HD) terminal housing measuring just 12 mm wide. In addition to the complete integration of the EL7201-0010 into a standard control system, One Cable Technology-equipped motors reduce wiring costs and keep commissioning costs to a minimum.

OCT is also available as an option on the Beckhoff AM8000 servomotor series instead of the traditional resolver interface. The servo terminal extends the modular and compact drive system even further with more scalable options. In addition to solutions for stepper and DC motors, the servo terminals are designed for highly dynamic servo positioning tasks due to integrated, fast control technology.

It also has full integration of the EtherCAT industrial Ethernet system. In addition to motion control improvements, the user benefits from further EtherCAT advantages, such as short cycle times, low jitter and simple diagnostics. The monitoring of numerous parameters, such as overvoltage and undervoltage, overcurrent, terminal temperature or motor load via the calculation of an I²T model allows for continued operational reliability.

Beckhoff Automation

www.beckhoff.com 

- Edited by CFE Media. See more Control Engineering motor and drive products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me