Servo inverter

The I700 Servo Inverter by Lenze Americas is designed for multi-axis applications and features short cycle times and 32-bit signal resolution for demanding environments.

02/06/2012


Lenze Americas' Servo Inverter i700 is designed for multi-axis applications, which simplifies machine design, build and commissioning. Well-suited for material handling systems, the new drive system features an easy assembly concept and is notably compact and flexible. Extremely short cycle times, 32-bit signal resolution and an overload capacity of more than 200% make the new i700 equally suited for simple positioning tasks and highly dynamic, precise, multi-axis applications in handling and packaging machines or robot applications.

The Servo Inverter i700 single-axis and double-axis modules offer a power range from 0.37 to 15 kW, along with appropriate power supply modules. Plug connectors enable easy wiring. Under normal operating conditions the power supply modules do not require filtering or DC fusing, and have a built-in dynamic brake chopper. Intermediate electrical connections between the i700 drives are cable-free, using an innovative rail system, and are easily installed by setting connector arms.

Lenze offers a variety of i700 cooling technologies, including cold plate, push-through technology, and panel mounted units. Supporting the full spectrum of motor technologies, from standard 3-phase motors to synchronous servomotors, the i700 uses a single interface for simple engineering. The dynamic motor control is suitable for a wide range of applications.

Intuitive software tools and a central engineering interface, make it simple to integrate the i700 into automation architectures through EtherCAT. Automatic download of parameters and firmware, along with auto-tuning functions, ensure fast commissioning. Additionally, the i700 features integrated safety functionality to simplify the machine design. "Safe Torque Off (STO)" is provided as a standard feature. In order to implement extended safety networks, Lenze offers variants, for example, SS1, SS2, SOS, SLS, SDI or SLI, which achieve the highest safety level (SIL 3, PL e) over EtherCAT (FSoE).



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.