Serial synchronous interface module for motion control, position sensing applications

Opto 22 Snap-SCM-SSI serial module offers a communications interface between digital encoders and Snap PAC System I/P processors or programmable automation controllers; designed for use in motion control and other tracking and identifying applications.

12/27/2010


The new Snap-SCM-SSI I/O module from Opto 22 offers a communications interface between digital encoders and Snap PAC System I/O processors or programmable automation controllers. The Snap-SCM-SSI I/O module provides two isolated serial synchronous inputs (SSI) for acquiring data from optical and mechanical encoders and other types of linear and rotary transducers.

Designed for use in motion control and other applications where tracking and identifying the movement and position of machinery or components is critical, the Snap-SCM-SSI connects to and accepts input from either binary or Gray code encoders, allowing the module to process and communicate position-related data from heavy duty industrial machinery and apparatus (such as floodgates, drawbridges, and rotating or elevating platforms) as well as machine tools, stepper motors, servos, and other moving or robotic components.

The Snap-SCM-SSI accomodates an SSI clock frequency of up to 2.5-MHz, functions at cable lengths up to 500-ft, and can be configured for clock frequency, data bits (i.e., encoder resolution), time interval between data samples, and more. The module can be used with both Snap PAC Ethernet (EB-series) and Snap PAC serial (SB-series) I/O processors, standard Snap PAC standalone and rack-mounted controllers, and all Snap PAC Wired+Wireless controllers.

www.opto22.com

Opto 22

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.