Self-assembling robots from MIT have simple design

Resolves problem for modular-robotics community: Small cubes with no exterior moving parts can propel themselves forward, jump on top of each other, and snap together to form arbitrary shapes. Link to video of the robots.

10/03/2013

Flash is required!

Daniela Rus (center) is a Professor of Electrical Engineering and Computer Science and Director of the Computer Science and Artificial Intelligence Laboratory at MIT in Cambridge, Massachusetts, USA. Working postdoctoral associate Kyle Gilpin (plaid) andIn 2011, when an MIT senior named John Romanishin proposed a new design for modular robots to his robotics professor, Daniela Rus, she said, “That can’t be done.”

Two years later, Rus showed her colleague Hod Lipson, a robotics researcher at Cornell University, a video of prototype robots, based on Romanishin’s design, in action. “That can’t be done,” Lipson said.

In November, Romanishin — now a research scientist in MIT’s Computer Science and Artificial Intelligence Laboratory (CSAIL) — Rus, and postdoc Kyle Gilpin will establish once and for all that it can be done, when they present a paper describing their new robots at the IEEE/RSJ International Conference on Intelligent Robots and Systems.

Known as M-Blocks, the robots are cubes with no external moving parts. Nonetheless, they’re able to climb over and around one another, leap through the air, roll across the ground, and even move while suspended upside down from metallic surfaces.  

Inside each M-Block is a flywheel that can reach speeds of 20,000 revolutions per minute; when the flywheel is braked, it imparts its angular momentum to the cube. On each edge of an M-Block, and on every face, are cleverly arranged permanent magnets that allow any two cubes to attach to each other.

“It’s one of these things that the [modular-robotics] community has been trying to do for a long time,” says Rus, a professor of electrical engineering and computer science and director of CSAIL. “We just needed a creative insight and somebody who was passionate enough to keep coming at it — despite being discouraged.”

Embodied abstraction

As Rus explains, researchers studying reconfigurable robots have long used an abstraction called the sliding-cube model. In this model, if two cubes are face to face, one of them can slide up the side of the other and, without changing orientation, slide across its top.

The sliding-cube model simplifies the development of self-assembly algorithms, but the robots that implement them tend to be much more complex devices. Rus’ group, for instance, previously developed a modular robot called the Molecule, which consisted of two cubes connected by an angled bar and had 18 separate motors. “We were quite proud of it at the time,” Rus says.

According to Gilpin, existing modular-robot systems are also “statically stable,” meaning that “you can pause the motion at any point, and they’ll stay where they are.” What enabled the MIT researchers to drastically simplify their robots’ design was giving up on the principle of static stability.

“There’s a point in time when the cube is essentially flying through the air,” Gilpin says. “And you are depending on the magnets to bring it into alignment when it lands. That’s something that’s totally unique to this system.”

That’s also what made Rus skeptical about Romanishin’s initial proposal. “I asked him build a prototype,” Rus says. “Then I said, ‘OK, maybe I was wrong.’”

Sticking the landing

M-Block cube robots rest on a work table in the Distributed Robotics Lab in CSAIL at MIT in Cambridge, Massachusetts, USA. The robots are 50mm cubes that can reconfigure themselves into various arrangments using self-propulsion and magnets. The work is diTo compensate for its static instability, the researchers’ robot relies on some clever engineering. On each edge of a cube are two cylindrical magnets, mounted like rolling pins. When two cubes approach each other, the magnets naturally rotate, so that north poles align with south, and vice versa. Any face of any cube can thus attach to any face of any other.

The cubes’ edges also have a slight bevel, so when two cubes are face to face, there’s a slight gap between their magnets. When one cube begins to flip on top of another, the bevels, and thus the magnets, touch. The connection between the cubes becomes much stronger, anchoring the pivot. On each face of a cube are four more pairs of smaller magnets, arranged symmetrically, which help snap a moving cube into place when it lands on top of another.

As with any modular-robot system, the hope is that the modules can be miniaturized: the ultimate aim of most such research is hordes of swarming microbots that can self-assemble, like the “liquid steel” androids in the movie “Terminator 2.” And the simplicity of the cubes’ design makes miniaturization promising.

But the researchers believe that a more refined version of their system could prove useful even at something like its current scale. Swarms of mobile cubes could temporarily repair bridges or buildings during emergencies, or raise and reconfigure scaffolding for building projects. They could assemble into different types of furniture or heavy equipment as needed. And they could swarm into environments hostile or inaccessible to humans, diagnose problems, and reorganize themselves to provide solutions.

Strength in diversity

The researchers also imagine that among the mobile cubes could be special-purpose cubes, containing cameras, or lights, or battery packs, or other equipment, which the mobile cubes could transport. “In the vast majority of other modular systems, an individual module cannot move on its own,” Gilpin says. “If you drop one of these along the way, or something goes wrong, it can rejoin the group, no problem.”

In ongoing work, the MIT researchers are building an army of 100 cubes, each of which can move in any direction, and designing algorithms to guide them. “We want hundreds of cubes, scattered randomly across the floor, to be able to identify each other, coalesce, and autonomously transform into a chair, or a ladder, or a desk, on demand,” Romanishin says.

- Edited by CFE Media. See more Control Engineering robotics coverage.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me