School HVAC Noise Levels a Case of Internal Affairs?

There are many reasons for poor performance in school, but one that isn't widely recognized is ventilation noise in classrooms. Ricardo Gamboa, manager of engineering and technical services for performance materials for Denver-based Johns Manville believes it's not an issue to be taken lightly. "It is a big problem.

08/01/2004


There are many reasons for poor performance in school, but one that isn't widely recognized is ventilation noise in classrooms. Ricardo Gamboa, manager of engineering and technical services for performance materials for Denver-based Johns Manville believes it's not an issue to be taken lightly.

"It is a big problem. We are adults. If we only hear one or two words, we can make [the rest] up, we can bridge and get a sense of what is being said," he says. "Kids have a very limited vocabulary, and they can't do that, so they lose all sense of what is being said or the actual meaning of the conversation."

Gamboa has high hopes for a standard that addresses this issue. ANSI S12.60, Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools , was recently developed by the Acoustical Society of America. However, it has yet to be adopted into code.

In the meantime, Gamboa and his Johns Manville colleagues push for what they see as an important tactic in controlling acoustics—and temperature—in classrooms: internal duct lining. Eric Schakel, market manager of commercial air-handling products for the company, explains that there was a trend away from installing internal duct insulation in schools over the last 10 to 15 years, due to fears of potentially harmful effects of fiberglass. However, Charles Cotrell, director of technical services for the North American Insulation Manufacturer's Association, notes that in 2002, the International Agency for Research on Cancer concluded that fiberglass is not known to be a carcinogen to humans. As a result, Schakel says, his company has noticed an increase in the use of fiberglass duct lining.

Additionally, Schakel points to ASTM C1071, Standard Specification for Fibrous Glass Duct Lining Insulation . While this standard doesn't directly address classroom acoustics, it does cover "fibrous glass insulation used as a thermal and sound absorbing liner for interior surfaces of ducts." As such, says Schakel, it allows engineers to specify insulation based on noise absorption and thermal capabilities, whereas in the past, engineers often specified various thicknesses and materials without a point of reference as performance.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me