School District of the City of York, Arthur W. Ferguson Elementary School

New construction: School District of the City of York, Arthur W. Ferguson Elementary School; Barton Associates Inc.

Source: Barton Associates Inc.

08/09/2012


The school is not only the first LEED Platinum Certified public elementary school in Pennsylvania but is only the second school in Pennsylvania to achieve LEED Platinum from the U.S. Green Building Council. The project also received the 2011 Overall Design Award from the Green Building Association of Central Pennsylvania. (Click to enlarge)Project name: School District of the City of York, Arthur W. Ferguson Elementary School

Location: York, Pa.

Firm name: Barton Associates Inc.

Project type, building type: New construction, school (K-12)

Project duration: 3 years

Project completion date: Aug. 16, 2010

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $5.8 million

Engineering challenges

The Ferguson Elementary school project had very interesting challenges that the design team needed to address throughout the project. The site was the home to the existing elementary school that needed to remain occupied while a new facility was constructed on site. The school district also wanted to implement the most energy-efficient system that was possible, which could be constructed in a phased approach. The elementary school phasing created a separate administration/multipurpose section of the facility that was segregated from the classroom section and connected only by a walkway/corridor with a playground underneath. The school district desired that the design team reduce energy use of the kitchen exhaust and makeup systems for a more energy-efficient building. The school district also desired that the design team reduce energy use of the facility by reducing power consumption of the lighting systems. The goal of the project was to implement a lighting power budget of 0.7 watts per sq ft and still keep the light level appropriate for a classroom.

Solutions

An HVAC system evaluation was performed and a geothermal heat pump system was chosen. The system analysis showed that a geothermal heating and cooling system would have a 7-year payback. The geothermal well field was to be installed early so that the new building could be constructed while the existing building was still operational. Both buildings were overlaid, along with the new and existing electrical service and plumbing utilities, to locate what portions of the site could be utilized for the geothermal well field. The geothermal well field was designed to accommodate the existing building and new facility by increasing the well depth to 450 ft, and very specific pipe routing was specified as the existing building was only 15 ft away from the new facilities’ mechanical room and pipe entrance. The corridor connects the three-story classroom area to the administrative office and main entrance. Because the administrative area needed utilities and the main electrical and mechanical room was located in the three-story classroom wing, the 5-ft-wide corridor ceiling was the only direct path connecting the two building sections. Close coordination through the design and construction process for all disciplines had to occur to locate the piping, conduits, and duct through that bridge connection to accommodate services in both phases of the facility. We coordinated work with the kitchen equipment vendor and consultant to integrate the exhaust fan and makeup air unit operation with the HVAC controls to the kitchen hood operation so that the system operates at the flow rate needed based on the food service equipment being used rather than the maximum flow at all times. We selected and spaced light fixtures to meet the foot-candle level while reducing the watts required by the lamps. Daylight controls with digital ballasts were implemented to adjust the light level on a per row basis as the lights move away from the windows.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.