Scanning x-ray detectors for dental, medical imaging

Dalsa’s CCD/TDI x-ray imaging module provides higher resolution with easy Ethernet connectivity.

01/21/2011


Dalsa Corporation [TSX: DSA], a global leader in digital image sensing technology, produces its Argus platform of CCD/TDI-based X-ray image scanners developed for use in the medical and dental fields. DALSA’s CCD/TDI Argus x-ray imaging moduleArgus modules include high resolution scintillation technology and standard Ethernet connectivity, allowing images to be ported directly to the host computer for image processing. Assembled with advanced MEMs fabrication techniques in Dalsa’s own wafer foundry, they also reportedly provide unmatched resolution by joining multiple silicon detectors for large fields of view up to 44 cm wide.

Patented TDI Technology

The Argus platform incorporates Dalsa’s patented TDI (Time Delay and Integration) technology for reported high sensitivity, unmatched detective quantum efficiency (DQE) and incredible image quality at lower patient exposures.

"A good X-ray detector has to absorb and utilize as many X-ray quanta as possible in order to minimize the patient exposure to X-rays, while producing the highest resolution, contrast and image quality. Dalsa’s new cost-effective Argus platform provides such performance in a module that is easy to integrate in the X-ray imaging system,” says Behnam Rashidian, Argus product manager.

Argus–PAN Features

The Argus-PAN is designed for extra-oral imaging applications. The extremely low noise operation, coupled with high performance 16-bit ADC, purportedly provides up to 80dB of dynamic range. Primary Argus-PAN features include:

  • Assembled with advanced MEMs fabrication techniques for high resolution and large fields of view up to 44 cm wide.
  • Flexible and robust module form factor for ease of integration into existing panoramic dental systems.
  • High dynamic range and sensor large full well enables high contrast images.
  • Low sensor readout noise provides images with high clarity.
  • 100 Mb Ethernet interface for ease of interface to the X-ray modality.
  • 16bit ADC for high precision image capture.
  • Anti-blooming, preserves image integrity on the edges and in bright spots of the image.

Argus Modules

In addition to the Argus-PAN, the Argus line scan TDI X-ray imaging platform will support two other modules, the Argus-DQ, and the Argus-Scan. The Argus-DQ features an advanced scintillation technology for ultra-high resolution and low noise applications like mammography. The Argus-SCAN will provide an extremely wide 44 cm wide field of view ideal for applications such as body scanning and trauma imaging.

Life Science Imaging

www.dalsa.com Dalsa Corporation



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.